1
Q

What’s DS I stand for

A

Direct, spark, igniter

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
2
Q

What’s IP stand for?

A

Intermittent pilot

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
3
Q

What’s HSI stand for?

A

Hot surface igniter

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
4
Q

An automatic ignition system uses what flame sensing device

A

Flames sensor
Flame rectifier

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
5
Q

What gas control valve uses DSI
IP
HSI

A

Smart valve

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
6
Q

What’s the benefit of a redundant gas valve?

A

It can’t stop the flow of gas

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
7
Q

What’s the function of flame sensor?

A

Flame rectification
Play conductivity

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
8
Q

On a spark, ignition system, the gap between the igniter sensor, and the grounding should be

A

1/8

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
9
Q

What is meant by pre-purge

A

The inducer motor starts for 15 seconds to ensure everything is good

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
10
Q

What is meant by trial for ignition

A

Gas valve opens to heat a heat exchanger what closes and retries ago

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
11
Q

What is meant by system lockout

A

After a given amount of times, the furnace will stop working for for a set time. Unless it’s been reset.

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
12
Q

Describe intermittent ignition

A

Ignition that continues to function during the time The flame is present.

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
13
Q

Describe, interrupted ignition

A

Ignition that ceases after trial for ignition.

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
14
Q

Describe continuous pilot

A

Pilot that burns throughout entire time. The burner is in service or not.

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
15
Q

Describe proved pilot

A

Pilot flame supervised by primary safety control that senses presence of the pilot admitting into the burner

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
16
Q

What’s the warm-up time for an HSi igniter?

A

17 to 34 seconds

17
Q

What’s the area of the ground compared to the flame sensor?

A

4:1

18
Q

I see inducer continues to run after the burners shut down. What is it called?

A

Post purge cycle

19
Q

What’s the approximate temperature of the HSI igniter when it’s lit up?

A

2600 Fahrenheit

20
Q

IDM is powered for a preset period of time how long

A

15 seconds

21
Q

When does the blower get energized when calling for heat?

A

Approximately 45 seconds seconds depending on Blower really