Electrics Flashcards
Connecting two 12V 40Ah capacity batteries in series will result in a total voltage and capacity respectively of
24V, 40Ah
The connection in parallel of two 12V 40Ah batteries –>
12V 80Ah
Lead Acid Batteries
If one of the 12 cells of a lead-acid battery is dead, the battery is UNSERVICABLE
The voltage, of a fully charged lead-acid battery cell is 2.2V
A test to assess the state of charge of a lead-acid battery would involve COMPARING THE “ON LOAD” AND OFF LOAD” BATTERY VOLTAGES
Alkali Battery (Nickel Cadmium)
*can be recharged
*low cost cycle
*tough
- low energy density
- memory effect
- contains toxic metals
When carrying out a battery condition check using the aircraft voltmeter: a load should be applied to the battery in order to give a better indication of condition
The capacity of an accumulator is: the quantity of electricity that the battery can supply during discharge.
NiCad compared Lead Acid
*reduced charging time
*constant output voltage
Motor çalıştığında ammeter anlık olarak akım piki gösterir, bu normal. Ancak uzun süre devam ederse kontrol et.
Battery control unit, bataryayı izole eder:
*şarj tamamlandığında
*akü ısındığında.
Compass Deviation Magnetic Variance True
Compass Dairy Milk Very Tasty
DC generators are connected IN PARALLEL to provide maximum power.
Type of windings commonly used DC Starter motors are series wound
Series wound DC motors are best for application that require high startup torque, without the need for speed regulation.
Shunt wound DC motors are used in applications where the required startting torque is low, but good speed regulation is important
Compound wound hem paralel hem seri, yüksek tork yüksek
The conditions to be met to activate a shunt generator are:
Presence of a permanent field
Minimum rotation speed
Voltage Regulator
The power required for field excitation of the main rotor in modern constant frequency alternators is directly controlled by the VR
*Voltage regulator of DC generator is connected in series with the shunt field coil.
Assume a constant speed DC generator providing a constant output voltage. If the electrical load increases the VR will increase the intensity of the excitation current.
*VR DC jeneratörde paralel (shunt) bağlanan ekipmanlara seri bağlıdır.
BUSBAR - distribution point for electrical power
Vital busbars - undercarriage selection, emergency lighting, fire detection and extinguishing circuits
Essential busbars - supply equipment essential to ensure the safe flight of an aircraft
Non Essential busbars - galley supplies, cabin entertainment services
Hot buses or direct buses directly connected to ______
BATTERY
Generatros when connected to the same bus bar, are usually connected in ________ mode
Paralel
The services connected to a supply busbar are normally in parallel so that isolating individual loads decreases the bus bar current consumption
Because the connection in parallel of electrical equipment on an AC bus bar, isolation of individual equipments: decreases the bus bar current consumption ??
DC to AC - Inverter-Static Inverter
AC to DC - Transformer rectifier Unit (TRU)