AC Electrical Power
Provided by 5KVA alternator on each engine for windshield anti ice and fog protection.
Main Batteries
Located in tailcone (Upper- Left/Lower-Right)
24volt
27/28 amp/hr = 30 minutes duration
38 amp/hr = 50 minutes duration
On the ground - Low voltage protection at 14v (inhibited during engine start)
Battery starts can be made above 0* C
Emergency Battery
24v - lead acid
Located in nose
1 hr duration
Only used when not powered by GPU/APU/GEN
White EMER illuminates when the EMER Batt is discharging
Ground protection cutoff at 14v
Delay application of power to EMER Batt during initialization due to BITs
Engine Generators
Starter/Generator 28vdc 300 amps Auto online when deec determines engines are at 95% of N1 idle Will not operate with GPU selected Cooled by scoop or fan on ground
GCU (Generator Control Units)
Regulate generator volage to 28vdc
Will auto disconnect if malfunction occurs
GPU
1500 amps
24-32volts - regulated to 28volts
White EXTERNAL POWER CAS - cable connected w/5v
AVAIL light int he EXT PWR S/I GPU on and within acceptable parameters
Isolation Contactors (Connect EMER Batt to Ess Busses)
Right contactor charges emer battery, L and R isolation contactors automatically close during flight to power ess busses from the EMER BATT
Essential Contactors
Close to provide power from the GEN bus to the Ess buses. Auto open during engine start.