Electrical Rough Flashcards
Electrical boxes are to be installed plumb, level, and secure. What is the tolerance?
No tolerance
A/C Disconnects
40” AFF
Bath GFCI & Switches
48”
Bath GFCI (installed sideways under medicine cabinets)
48½”
Dishwasher/Disposal (set box ¾” past stud for cabinet)
16”
Doorbell Push Button
42”
Doorbell Chime (hung horizontally)
12” from the lid
Dryer
40”
Electrical Panel (to center of the meter)
48”- 60” above finished grade
Electrical Panel (bottom of panel to AFF)
28”
Exterior GFCI
16”
Garage GFCI
46”
Garage door pushbutton pre-wire
60”
Garage door sensor pre-wire
12”
Kick Lights
16”
Kitchen GFCI
48”
Microwave (set box ¾” past stud for cabinet)
80”
Range (free standing)
On bottom plate
Receptacles
16”
Switches
46”
Under Counter Florescent Lights
55”
Vanity lighting w/8’ plate heights
92”
Vanity lighting w/9’ & 10’ plate heights
96”
Wall Mount Double Oven (home specific)
74”
Washer
40”
Distances fixtures are to be kept from fire sprinkler heads:
Can light under 250W
6”
Distances fixtures are to be kept from fire sprinkler heads:
Can light over 250W
12”