Electrical Jeopardy Flashcards
The STANDBY PWR OFF (amber) light when illuminated, indicates one or more of the following buses are unpowered: ____, ____, or ____.
-AC standby Bus
-DC Standby Bus
-Battery Bus
When does the BAT DISCHARGE Light (Amber) illuminate?
When excessive battery discharge is detected on the main battery and/or auxiliary battery
When will the generator DRIVE (Amber) light illuminate?
-IDG failure
-Engine shutdown
-IDG disconnected by activation of the DISCONNECT switch
-IDG auto-decouple due to high oil temp (182C).
How long will two fully charged batteries provide standby power?
Two fully charged batteries have sufficient capacity to provide standby power for a minimum of 60 minutes.
What does the BUS TRANSFER switch, in the AUTO (guarded) position, allow?
Allows the bus tiebreakers to operate automatically to maintain power to AC transfer buses from any operating generator or external power.