Electrical Emergencies Flashcards

You may prefer our related Brainscape-certified flashcards:
1
Q

ELECTRICAL FAILURE - ONE AMMETER OA

A
  1. ALTERNATOR SWITCH…..OFF
  2. CIRCUIT BREAKERS………CHECK
  3. ALT SWITCH……………………ON

IF POWER NOT RESTORED

  1. ALTERNATOR SWITCH…..OFF
  2. ELECTRICAL LOAD…………<60A
How well did you know this?
1
Not at all
2
3
4
5
Perfectly
2
Q

ELECTRICAL FAILURE - TWO AMMETERS OA

A
  1. ALTERNATOR SWITCHES……OFF
  2. ELECTRICAL LOAD……………..REDUCE
  3. CIRCUIT BREAKERS……………CHECK
  4. ALTERNATOR SWITCHES…..ON INDIVIDUALLY

IF POWER IS RESTORED ON ONE

  1. OTHER SWITCH………………….OFF
  2. ELECTRICAL LOAD………………<60A

IF POWER IS NOT RESTORED
7. BATTERY SWITCH………………OFF
ALTERNATOR SWITCHES……..ON INDIVIDUALLY

IF POWER RESTORED ON ONE OR BOTH
9. ELECTRICAL LOAD…<60A

IF POWER IS NOT RESTORED, PROCEED VFR TO NEAREST AERODROME. IF IN IMC, RATION REMAINING BATTERY POWER FOR AN APPROACH AND TO OBTAIN A CLEARANCE.

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
3
Q

ELECTRICAL OVERLOAD

A
  1. ALTERNATOR SWITCHES…….OFF
  2. BATTERY SWITCH………………..OFF

IF ALT LOADS ARE REDUCED
3. ELECTRICAL LOAD………………<60A

IF ALT LOADS ARE NOT REDUCED

  1. ALTERNATOR SWITCHES…..OFF
  2. BATTERY SWITCH……………….AS REQUIRED
  3. ELECTRICAL LOAD……………..REDUCE
How well did you know this?
1
Not at all
2
3
4
5
Perfectly