equipment lighting is used to provide
vision during night operation. machine operator safety . operator convenience . unit appearance
battery group disconnect switch
will prevent accidental slow discharge of battery group when unit is in park and not operating . can be connected in series with negative or positive battery leads
circuit protection devices
fuses and breaker panels . prevent machines electrical components from being destroyed by large current flows
main circuit protection device
usually 60 to 80 amps . protect entire machines electrical circuits . connected in series to machine fuse breaker box
type 1 circuit breaker
used when electrical current flow needs to be restored quickly . circuit opens and closes when a bimetal strip heats up and cools down . headlight circuits would use this type
type 2 circuit breaker
come equipped with a heat -producing resistor . this resistor holds the circuit breaker in the off ( open) position while the breaker rating is exceeded . used in non critical circuits like interior cab lighting
type 3 circuit breaker
have a manual reset button . can be used in non critical circuits that can remain non energized until the circuit is manually reset . used in equipment mounted signage
how do you properly size a circuit protection device
P = I x E or watts = amps x volts
high beam head lamps produce what for wattage
high wattage usually 80 watts
low beam lights produce what for wattage
low wattage usually 60 watts
flood / working lamps are connected where in the electrical circuit
connected into the key switch controlled circuits
why do you want flood / working lamps to be connected into the key switch control circuit
so you wont drain your battery when the unit is shut off
tail lamps are used for
used to outline a machines perimeter in poor visibility conditions . always red in color
clearance lamps are used for what
used to indicate the outer sides of a unit . usually amber in color
panel lighting
assists the operator in viewing the panel gauges . controlled by the master switch . able to alter the intensity of the light with the use of a lamp dimming solid state module
another way to dim panel lights other than a solid state module is by using a
series connected rheostat
why is it important to mount a rheostat away from flammable material
because the heat developed from the rheostat may start a fire
what is pulse width modulation
a digital signal that turns the circuit voltage on and off
what is duty cycle
the period of time a pulse width modulating signal is on compared to off
fiber optic cable is made out of what
plastic core surrounded by a polymer optical cladding sheath
when fiber optical cables fail what is the most likely source of the problem
the light source has malfunctioned
if the fiber optic cable is damaged you must
replace the cable . it cannot be repaired
when retrofitting break lights to LED you must also change
electromechanical flasher must be changed to a solid state electronic flasher
if you are going to use a electromechanical flasher with LED lights you must
install a series connected resistor