Electrical Flashcards
The two basic principles of operation for the 737 Electrical System are (Select ALL correct answers)
There is no paralleling of the AC sources of power.
The source of power being connected to a Transfer Bus automatically disconnects an existing source.
Sources of AC power include _____.
Select ALL correct answers
Battery through Static Inverters.
APU Generator
Engine-Driven Generators
Illumination of the Generator DRIVE light (amber) indicates the respective IDG experienced low oil pressure due to ________.
All of the Above
1) IDG failure
2) engine shutdown
3) IDG auto-decouple due to high oil temperature
Placing the GRD PWR switch ON _____.
connects external electrical power to both Transfer Busses
The BUS TRANSFER switch”,” in the AUTO (guarded) position”,” allows _______.
Bus Tie Breakers (BTB) to operate automatically
Which light(s) indicate(s) the APU generator is ready-to load”,” but not powering a bus?
APU GEN OFF BUS (bright blue)
If neither AC Transfer Bus is powered by an IDG”,” momentarily positioning either APU GEN switch to ON
______.
All of there Above
1) connects APU generator power to both Transfer Busses
2) illuminates the opposite SOURCE OFF (amber) light
3) disconnects external power”,” if connected, from both Transfer Busses
When the APU generator is powering Transfer Bus 1”,” Transfer Bus 2 can be powered with _____. (Select ALL of the correct answers.)
the APU Generator
IDG 2
The APU generator”,” operating in flight as a single electrical source ______.
automatically sheds the Galley and Main Busses
Moving a GEN1 or GEN 2 (Generator) switch to ON _____.
All of the Above
1) extinguishes the related GEN OFF BUS light
2) connects related IDG to Transfer Bus
3) disconnects previous source from the related Transfer
Bus
If the aircraft takes off with the APU generator powering both Transfer Busses”,” and the APU fails or is shut down”,” the _____ automatically connects IDGs to their respective Transfer Bus.
Automatic Generator On-line Feature
Illumination of the ELEC light (amber) _____ indicates a fault in the _____ Power System.
on the ground / DC or Standby
The Cross Bus Tie Relay automatically opens and isolates DC Bus 1 from DC Bus 2 ______.
at Glide Slope capture during a Flight Director or Autopilot ILS approach
The _____ Bus is always connected to the battery.
Hot Battery
BAT DISCHARGE light (amber) illuminates when _____ battery discharge is detected in the Main Battery and/or Auxiliary Battery.
excessive
When standby electrical power is required”,” the A/C standby bus is powered by _______.
the Main and Auxiliary Battery via the static inverter
Two fully-charged batteries have sufficient capacity to provide standby power for a minimum of _____ minutes.
60
With the STANDBY POWER switch in _____”,” the batteries power the standby loads after losing all engine or APU electrical power _____.
AUTO / in the air and on the ground
The _____ convert(s) battery power for use by the AC Standby Bus.
Static Inverter
The STANDBY POWER switch is in AUTO. With the loss of all engine and APU electrical power”,” the batteries will be powering the: (Select ALL correct answers.)
All
1) Battery Bus
2) AC Standby Bus via the static inverter
3) DC Standby Bus
4) Hot Battery Bus