Location of the APU battery?
Aft equipment bay
Max engine generator load?
40 KVA
Max APU generator load?
40 KVA
Max transformer rectifier unit (TRU) load?
120 AMPS
Max permissible time for ground operations with battery power only?
5 minutes
What is the reason for the Max ground operation time with battery power only?
To prevent ED1 and ED2 from overheating (fans are AC powered)
How many TRU’s are installed in the CRJ900
4
Where are the TRU’s located?
Nose compartment
The main battery is rated for?
17 amps / 24 volts
APU battery is rated to?
43 amps / 24 volts
How many generators are installed?
4
2 IDGS, 1 APU, 1 ADG
What is the function of the TRU’s
To convert 115 volt AC to 28 volt DC
How are the TRU’s cooled?
Individual fans
Which buses are powered when the battery master switch is selected on?
Main battery direct bus
APU battery direct bus
DC battery bus
If the main buses are powered, are the essential buses automatically powered?
Yes