Electrical Flashcards
AC sources
AC Generator (x2)
APU AC Generator
External Power
DC sources
DC Converters (115VAC to 28VDC)
SLAB (24VDC)
AC Gen locations
MGB Accessory Modules
AC Gen output
30/45 KVA, 115 VAC, 3 Phase, 400 Hz
APU Gen output
20/23.8 KVA, 115 VAC, 3 Phase, 400 Hz
Generator Control Unit (GCUs) monitor what?
Overvoltage
Under-voltage
Under-frequency (on ground only)
Feeder Fault (open or short)
External Power monitor regulates what?
Phase rotation
Overvoltage
Under-voltage
Under-frequency
Over-frequency
Automatic AC bus switches compensates for AC Gen load. AC bus switching prioritizes what two systems?
1: Hydraulic back up pump
2: Rotor De-Ice
Gens may not reset in flight if Nr is below ____%
97%
“APU GEN ON” indicates what?
The APU Gen is the only source of AC power
DC Converters are located where
LH and RH J-Boxes
DC Converter output
28 VDC, 200 Amps
Main aircraft battery output
SLAB: Sealed Lead-Acid Battery
24 VDC, 5.5 amp hrs
SLAB Primary and Secondary functions
Primary: APU start
Secondary: Emergency DC power
SLAB life is ____ mins w/out shedding and _____ w/ shedding.
W/out shedding: 34 mins
W/ shedding: 41 mins