Eaton Ch6 Flashcards
A strainer is called a______ filter
Fine
Coarse
Media
Absorbent
Coarse 
A particle one micron in size equals_____ inch
.000583.
.7053.
.00275.
.000039.
.000039. 
A filter designed to signal the operator when the element needs cleaning is called a(n) ______ filter
Circulating
Off-line
Absorbent
Indicating
Indicating 
Three general areas for locating a filter are Inlet, pressure and______ lines
Pilot
Return
Flow
Relief
Return
What type of filter element provides precise control of pore size?
Cylindrical
Sub plate
Surface
Pleated
Surface 
Filtering materials are classified as absorbent or _____
Mesh
Adsorbent
Fiber
Depth type
Adsorbent
What type of filter passes the entire flow entering it’s inlet through the element.
Proportional flow
Indicator type
Full flow
Reverse flow
Full flow
The smallest particle an eye can see is approximately _______ microns
25
40
50
75
40
Hydraulic circuit components fail as a result of contamination and ________
Design
Phase
Static
ISO
Design
If the fluid within the hydraulic pump, clearances become heavily contaminated,______ Will probably occur
Cavitation
Fatigue
Aeration
Seizure
Seizure
Which of the following is not a mechanism of wear
Adhesion
Filtration
Fatigue
Cavitation
Filtration 
Contamination blockage, which prevents and then allows a solenoid spool to shift is called a _______failure
Degradation
Catastrophic
Transient
Critical 
Transient
An increase in the pressure differential across a filter will cause a(n)______ in power consumption
Increase
Half wave
Decrease
Beta ration
Increase 
When specifying the correct filter for a given application, which of the following would not be considered?
Weight of particles to be held
Flow rate capacity
Flow sampling method
Pressure drop through element
Flow sampling method
Which is not a source of contamination in a hydraulic system?
Ingresses
Entrained
Internally
Built in
Entrained
The preferred location for dynamic sampling is directly______ of the return line filter
Downstream
Midstream
Center
Upstream
Upstream

After hydraulic system assembly, tubing must not be soldered, welded or_______
Flared
Threaded
Brazed
Plugged
Brazed
When transferring, clean oil, the transfer pump should be equipped with a_____ filter
Beta
Coarse
5 Micron
Mesh
5 micron
Filters that can trap much smaller particles than inlet line strainers are______ ______ Filters.
Pressure line
Return line
Off-line
Pilot line
Pressure line
The higher the sieve or mesh number the ____ The screen.
Thicker
Finer
Thinner
Coarser
Finer
To test for material compatibility, the filter element is immersed for______hours in system fluid
59
63
84
72
72
In cylindrical shape to filter elements,_______ tubes are used to support the Media against pressure differential.
Stainless
Flared
Perforated
Bypass
Perforated 
Hydraulic fiberglass filter elements tend to have a________ filtering structure
Stainless
Mesh
Surface
Pleated
Pleaded
To eliminate the possibility of filter element collapse , a_______ valve is used
Bypass
Inlet
Rotary
Check
Bypass 
To monitor initial and subsequent levels of contamination_______ points must be provided
Filter
Sampling
Static
Dynamic
Sampling