E-2 HEMTT Flashcards
What does HEMTT stand for?
heavy expanded mobility tactical truck
How many gls does the HEMTT hold?
2,500 gls
What temperature does HEMTT operate in?
-25 to 120 *F
How high can the HEMTT ford water? for how long?
48inch
5mins
HEMTT turning radius?
105ft
HEMTT top speed with full load?
55mph
Left and right hose reel length? and nozzle diameter ?
1 1/2 x 50ft length x2 1/2 inch (nozzle)
Delivery Pump GMP and type ?
300 GMP, centrifugal pump
Delivery pump high idle RPM?
1500 RPM
What is PTO ?
Power take off
drives pump
Auxiliary Fuel delivery pump GPM and volts/
25 GPM and 24 volts
What percent of explosion in HEMTT?
3%
A receptacle used for?
self-loading operation (bottom loading )
What do V7 and V8 do?
control the flow of fuel to the hoses on the right and left
V7/V8 valve delivery rates 1-5,5,6,7,8 ?
by 15s
1-5 = 105 (+/- 5) 5 = 90 6 = 75 7 = 50 8 =15
Discharge Line Pressure Gage (DLPG)
indicates pressure between hose reels
Flow Meter and Reset Knob
reset meter after each issue
Venturi nozzle pressure gauge (VNPG)
indicates pressure when using the D1
V6 used for ?
fuel / defuel value
IN for fueling operations
OUT for defueling
Length of hose lines ?
50ft x 21/2 inch
Flow valve V11 does what ? 1 notch = how many gls?
flow of fuel to unload filtered
1notch = 25gls
C receptacle used for?
bulk unfiltered
3inch connections
what is v1?
emergency valve/manual control valve
what is v18?
bulk delivery valve
full flow 300GPM