Drager X 5000 gas meter applications :
Natural or methane gas leak, explosion, confined space, trench rescue, metro-rail, O2 enriched or depleted atmosphere, hazmat, overhaul
What are the 4 gas specific sensors
O2, CO, H2s, HCN
oxygen, carbon monoxide, hydrogen sulfide, hydrogen cyanide
The Drager X 5000 is intrinsically safe to _____ and resistant to _____, _____, _____ _____.
electromagnetic interference, water, dust, impact vibrations
The Drager X 5000 needs to be exposed to fresh air ______ and ______ use to maintain it calibration
before and after
Gas specific calibrations are performed by _____ and how often _____
Hazmat squad, 6 months
The Drager X 5000 displays in
PPM parts per million
A _____ in the upper right corner means_____
X, system failure
The Drager X 5000 is not guaranteed to be intrinsically safe in atmospheres greater than _____ %, due to danger of explosion
23.5
The Alarm 1 is set at _____ LEL and alarm 2 is set at _____ LEL
10% and 20%
true false During operation, if the alarm sounds leave the area immediately.
true
Battery alarms _____ of full battery, a symbol will flash on the right side.
1/3
The Drager X 5000 battery will last _____ minutes after alarm
20 minutes
The Drager X 5000, Replace the batteries if less than _____ full
3/4
bump test is performed every _____ days or when _____ by _____
180, registered readings, hazmat
TB 106 LLCCES, LLCCES stands for
lookout, location, conditions, communications, escape routs, safety zone / equipment