DPO Flashcards
Finish Mechanical Foam is a….
Completed product after air is introduced in the solution and leaves the nozzle
The purpose of the check valve in a fire department connection is to prevent…
Water from a sprinkler system from flowing back
Pump discharge pressures should not exceed ___psi unless the standpipe system has been designed to withstand higher pressures
185psi
Which type of fire pumps must be primed using an external priming device?
Centrifugal
Once the power take-off has been properly activated and the pump is engaged, the vehicle speedometer should show a speed of….
Slightly above 0 mph
A___distribution system is a network of water mains which provides circulating feed
Grid
Using the coefficient method, determine the pressure loss due to friction in the hose assembly
86.5 psi
Fire gels work by….
Entrapping water instead of air
A hydrant with the largest capacity will be one that is connected to a …..
Primary feeder
One method of calculating the capacity of a water shuttle operation in gpm is…..
Travel time divided by the required flow
The amount of work that a pump must do to produce a fire stream is the _____pressure
Pump Discharge
If a fire department connection is found inoperable, the best way to bypass it so operations can be performed is….
Stretch a medium size diameter supply line into the building and connect it to the standpipe hose outlet on the first floor
A dual pumping operation is…..
Placing one pumper at a hydrant and a second pumper connected intake to intake
Water flowing through hoses and appliances results in….
Friction Loss
Water temperature greater than 90 degrees F can cause _____in the fire pump
Decreased capacity
In a _______hydrant, a small drain valve opens as the hydrant is closed
Dry barrel
A piercing nozzle would be used on……
An attic fire
In-line relay valves allow for…..
Late arriving pumpers to hook up without interrupting operations
TO prevent water hammer, it is important to close nozzles, hydrants, valves, and hose clamps……
Slowly
An operator should prime a pump when operating…..
From a static source
When performing a capacity test, the desired net pump pressure should be _____psi
150 psi
The process that causes foam concentrate to move through an in-line foam eductor and into the water stream is the _____principle
Venturi
A _____depends on an external water source to provide the water
Dry Standpipe System
You should switch from pressure to volume when…..
More than half of the rated capacity of the pump will be required.
Compressed air form systems result in…..
Greater reach of fire stream
The selection of a proportioner depends on…..
Required ratio of foam and length and size of the attack line
The flow from a 1-inch nozzle tip with nozzle pressure of 50 psi is approximately ____gpm
210 gpm
To reduce carcinogen exposure after a fire, you should…..
Transport contaminated gear way from passenger compartments
All gauges used for service tests must have been calibrated within _____days
60
Pump discharge pressure is equal to…..
NP + TPL
_____ is a force-per-unit area with the measurements of force in pounds and the measurement of area in square inches
Pressure
Relay Operations should be shut down from the _____first
Attack pumper
Discharge manifolds may be used in relay operations to ……
Support more than one attack pumper
The pressure remaining once water has begun flowing is ______ pressure
Residual
Which is a fire hose appliance carried on a fire apparatus
Gated wye
The 50 percent pump capacity test is conducted at a net pump pressure of…..
250 psi for 10 minutes
Which valve determines whether the pump is operating in series or pressure mode
Transfer valve
Which foam has a surfactant added that it makes more fluid
Fluoroprotien
One way to increase the efficiency of water shuttle operations is to ….
Decrease the time required to fill the tender
An increase in vacuum while drafting indicates a……
Clogged strainer