A condition in which structure becomes unsafe due to possible collapse of the structure.
Strength Limit State
Excessive vibration is an example of strength limit state.
False - serviceability limit state
Resistance due to flexure is an example of serviceability limit state.
False
Working stress design and ultimate strength design are considered Limit State Design.
False
ASD and LRFD are generally the same in terms of providing adequate factor of safety.
False - same in serviceability, different in safety
Allowable stress must always be greater than or equal to actual stress is a strength design approach.
True
Overloading of structures and under strengthening of members are the factors of safety included in _________ design method.
Load Resistance Factor Design
In the allowable stress design method, the factor of safety is given to the resistance and no factor of safety is given to the actual ________.
Nominal Strength
The usual factor of safety given to beams and tension members is _____.
1.67
LRFD is limited to _____________ behavior.
inelastic
Connection design have bigger factor of safety than member design like columns and beams because connection failure are _________.
Brittle
The load factor used in strength design methods depends on ___________.
Type of Member
Since LRFD or Strength design method involved several factors of safety, the probability of failure is given by the margin of safety as well as ________.
Reliability Index
Importance of the member of the structure may affect the ∅ value.
True
LRFD or strength design method will always be safer and economical than ASD or WSD.
True