Door Systems Flashcards
Grey doors
Closed and inhibited
Green doors
Closed but not inhibited
White doors
Door open
Red door inside train
Door failed in closed position
Red door outside of train
Failed in the open position
Flashing red door
DER pulled to stage 2 position
Yellow doors
Door isolated
Empty door
Unknown status
What does the automatic selective door control (ASDC) do?
Prevents off side and off platform door releases
If you overshoot the stopping mark by 10m or more, will the doors be available for use?
No, they are unavailable and remain grey
What does the auto door inhibit do?
Prevents doors from closing after 60 secs
What will the HCMT assume of the platform of there is a substandard beacon read?
Assumes the platform is shorter and will inhibit the first or last saloon door
If one of the beacon readers fails, what is that referred to as?
A substandard beacon read
How do you override the ASDC?
A - announcement
S - SDU (check cameras to make sure your on plat)
D - door - open cab door and confirm
C - cover - lift correct side ASDC cover and press
After a DER is pulled, how long do you have to press the inhibit button? And how long does the inhibit last?
20 sec and 120sec