What is the Code used to get into the Keypad configuration to program the keypads address?
3577 (INST)
What is the Code used to get into Keypad Programming or Programmer Mode?
6653 (PROG)
What is the Code used to get into Diagnostics Mode?
2313 (DIAG)
What is the Default User Code?
99
On the Keypad Bus which color is Data in?
Yellow is data in and Green is data out
On the XR500 mother board, how many hard wired zones are there?
10 zones, two of which can be used as powered loop zones.
On the XR500 how many LX buses will the system support?
5 LX buses can be supported
How many Partition can the ZR500 support?
None but it will support 32 individual reporting areas, with common areas.
What is the difference between a Partition and a Area?
Each Partitions must be able to call a different phone number (Monitoring station) for reporting as well as be able to report different account numbers. The Areas can report different account numbers but they can only call the same phone numbers (Monitoring station).
How many zones can a XR500 support?
- 10 on board, 64 keypad bus zones and 500 LX bus zones.
What is different about zones 9 and 10?
Zones 9 and 10 are powered loop zones to support smokes and glass break detectors
Why should you never put a 24 hour burg device on zones 9 and 10?
When a sensor reset is done, zones 9 and 10 lose power to them which will put 24 hour Burg zones into alarm.
How many on board relays does the XR500 supply?
2
How many on board outputs does the XR500 supply?
6 (2 C form contacts and 4 open-collector outputs that go low when activated.)
How many Doors can the XR500 control?
16
On the XR500 how many supervised devises will the Keypad bus support?
16
What kind of Reader can be used with the XR500?
any reader that has a wiegand data output.
Are zones 9 and 10 rated as Class A or Class B fire zone?
Class B only
On the XR500, how many outputs can be added using the LX bus?
500