Distribution Systems Flashcards

1
Q
Air distribution arrangements:
1. single \_\_\_\_
2. terminal \_\_\_\_\_\_\_
3. induction \_\_\_\_\_\_
4. \_\_\_\_\_ zone
bypass \_\_\_\_\_ zone (terminal reheat)
A
  1. single zone
  2. terminal reheat
  3. induction reheat
  4. multizone
  5. bypass multi zone (terminal reheat)
How well did you know this?
1
Not at all
2
3
4
5
Perfectly
2
Q

Distribution arrangements can have two different types of air flow;
1.
2.

A
  1. constant volume

2. variable volume

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
3
Q

Residential is all ______ duct because it is cheaper

A

single

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
4
Q

Single zone distribution characteristics:

  1. responds only to one zone or ______ condition
  2. can be single or _____ fan
  3. can incorporate reheat coils for __________
  4. economizers can be used when OA is below ___
  5. constant volume or _______ volume air flow
  6. energy efficiency is ______
A
  1. space
  2. dual
  3. dehumidification
  4. 55F
  5. variable
  6. good
How well did you know this?
1
Not at all
2
3
4
5
Perfectly
5
Q

If static pressure in return is too high in return duct what happens?

A

It will be exhausted outdoors

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
6
Q

Terminal Reheat Distribution:

  1. Modification of single zone air and ______ systems
  2. Responds to ______ zones or space conditions
  3. can be single or _____ fan
  4. incorporates a ______ coil at each zone for individual temp control
  5. Terminal box can be reheat unit (medium velocity) or _______ unit (high velocity)
A
  1. water
  2. multiple
  3. dual
  4. reheat
  5. induction
How well did you know this?
1
Not at all
2
3
4
5
Perfectly
7
Q

Single Duct Terminal Reheat:

  1. Primary air supplied down the duct at approx ___F
  2. the air is reheated at the zone on a call for heat at the zone ________
  3. used in large buildings with many zones with large variations in ____
  4. ____ an energy efficiency system
A
  1. 55F
  2. thermostat
  3. load
  4. NOT
How well did you know this?
1
Not at all
2
3
4
5
Perfectly
8
Q

What does AHU mean?

A

Air handling unit

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
9
Q

What is a system that does not have any return air called?

A

make up air

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
10
Q

What happens when you block multiple diffuser outlets?

A

over pressurization in ducts

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
11
Q

What is the best way to fix over pressurization?

A

variable speed motor that can adjust to whatever demand is required

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
12
Q

What are VAV terminals? (Square/round box before diffuser outlet)

A

They talk to thermostats to adjust cooling/heating needs

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
13
Q

VAV terminals sometimes have an electrical _______ coil at the terminal

A

reheater

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
14
Q

VAV terminals control flow of air with _______ on the inlet

A

dampers

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
15
Q

If the thermostat tells the VAV it is too cold in the room it will _______ the damper to bring in less cool air

A

adjust

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
16
Q

Some reheat coils are hot ______ fed

A

hot water fed

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
17
Q

Where are economizers located?

A

outside air hood

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
18
Q

What is an enthalpy/temp sensor on an economizer?

A

tells the controller to open or close damper based on latent/sensible

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
19
Q

Economizer:

As outdoor air damper begins to modulate open the return air damper will begin to modulate closed to ensure correct ______ air is maintained

20
Q

Some economizers use outdoor air as ____ cooling for the building

21
Q

Set economizer at A,B,C,D settings based on what factors

A

temperature and relative humidity

22
Q

Single Duct; Terminal Reheat Distribution:

  1. economizers can be used to save on _______ costs
    - energy efficiency is poor
  2. Induction units were designed for use in exterior rooms of multi story buildings where a high sensible loss occurs, yet at the same time cooling is required in the interior of the building
23
Q

*Single Duct; Terminal Reheat Distribution; Induction Unit:

  1. Coils: Dual temp ______ (DTW) System
  2. Low/Med/High (LMH) __ System

Terminology:

  1. Primary air (______ from main equipment plenum)
  2. Secondary air (room induced by ________)
A
  1. water
  2. TW
  3. supply
  4. primary
24
Q

An induction box uses the Bernoulli principle to draw room air in and mix with the ______ air

25
Difference between an induction unit and VAV?
induction unit is a VAV but adds induced air for mixing purposes
26
Single Duct; Multi-zone: Modification of single duct system; All Air System 1. Two separate plenums; 1 for _____, 1 for ______
1. heat, cool
27
Single Duct; Multizone 1. Responds to multi-zone or space conditions (normally __ or less) 2. Hot deck temperature is determined by _______ stat 3. Cold deck temp maintained at __F 4. Zone air is mixed by zone mixing dampers located within ____ ________
1. 12 or less 2. outdoor stat 3. 55F 4. main plenum
28
what are mixing boxes used for?
to maintain temperatures so there is not swing in room temp from furnace coming on/off
29
Single Duct; Multizone 1. ____ supply duct to each zone 2. economizers can be used 3. Fan arrangement is _____ through 4. Induction unit __ normally used 5. Constant _______
1. one 3. blow 4. not 5. volume
30
Single Duct: Bypass Multizone; Modification of multizone; 1. Air and Water system: Has ___ separate plenums; 1 for _____, 1 for ______ cool 2. cold deck is maintained at ___F
1. one for cool, one for bypass cool | 2. 55F
31
Single Duct: Bypass Multizone 1. Responds to _____ or space temperatures 2. Normally used in milder climates as it uses return air heated by space as ______ heat 3. If further heating is required the system is equipped with _______ ______ coils at terminal box of each zone
1. zone 2. primary 3. terminal reheat coil
32
Single Duct: Bypass Multizone; 1. Terminal box may be ________ type 2. Fan arrangement is ____ ______ 3. Air supply is ______ ________
1. induction type 2. draw through 3. constant volume
33
Dual Duct System; 1. Most ________ type of system 2. All air system 3. Responds to unlimited number of _____ 4. Fan arrangment can be of two types; what are they?
1. expensive 3. zones 4. draw through or blow through
34
Dual Duct System; 1. Has two separate ducts; what are they? 2. ________ boxes located at each zone 3. Economizers not _________ 4. Single or _____ fan
1. hot duct, cold duct 2. Mixing 3. recommended 4. single or dual fan
35
Name a system that is NOT energy efficient
single duct terminal reheat
36
minimum fresh air?
20%
37
What applications are single duct terminal reheat systems used?
used in large buildings with variations in load
38
What type of system responds to an unlimited number of zones?
dual duct
39
Fan arrangement for single duct bypass multizone?
draw through
40
fan arrangement for single duct multizone?
blow through
41
Are induction units normally used in single duct multizone?
no
42
Where do Single Duct; Terminal Reheat Distribution; Induction Units get their primary air and induced air from?
primary air from main supply plenum secondary air from primary air
43
why would a single zone distribution system have a reheat coil?
dehumidification
44
Name two types of reheat coils?
hot water reheat or electric reheat
45
What is meant by induced air?
pulled in room temp air from the space
46
name five air distribution arrangements:
1. single zone 2. terminal reheat 3. induction reheat 4. multizone 5. bypass multi zone (terminal reheat)