Distribution Systems Flashcards
Air distribution arrangements: 1. single \_\_\_\_ 2. terminal \_\_\_\_\_\_\_ 3. induction \_\_\_\_\_\_ 4. \_\_\_\_\_ zone bypass \_\_\_\_\_ zone (terminal reheat)
- single zone
- terminal reheat
- induction reheat
- multizone
- bypass multi zone (terminal reheat)
Distribution arrangements can have two different types of air flow;
1.
2.
- constant volume
2. variable volume
Residential is all ______ duct because it is cheaper
single
Single zone distribution characteristics:
- responds only to one zone or ______ condition
- can be single or _____ fan
- can incorporate reheat coils for __________
- economizers can be used when OA is below ___
- constant volume or _______ volume air flow
- energy efficiency is ______
- space
- dual
- dehumidification
- 55F
- variable
- good
If static pressure in return is too high in return duct what happens?
It will be exhausted outdoors
Terminal Reheat Distribution:
- Modification of single zone air and ______ systems
- Responds to ______ zones or space conditions
- can be single or _____ fan
- incorporates a ______ coil at each zone for individual temp control
- Terminal box can be reheat unit (medium velocity) or _______ unit (high velocity)
- water
- multiple
- dual
- reheat
- induction
Single Duct Terminal Reheat:
- Primary air supplied down the duct at approx ___F
- the air is reheated at the zone on a call for heat at the zone ________
- used in large buildings with many zones with large variations in ____
- ____ an energy efficiency system
- 55F
- thermostat
- load
- NOT
What does AHU mean?
Air handling unit
What is a system that does not have any return air called?
make up air
What happens when you block multiple diffuser outlets?
over pressurization in ducts
What is the best way to fix over pressurization?
variable speed motor that can adjust to whatever demand is required
What are VAV terminals? (Square/round box before diffuser outlet)
They talk to thermostats to adjust cooling/heating needs
VAV terminals sometimes have an electrical _______ coil at the terminal
reheater
VAV terminals control flow of air with _______ on the inlet
dampers
If the thermostat tells the VAV it is too cold in the room it will _______ the damper to bring in less cool air
adjust
Some reheat coils are hot ______ fed
hot water fed
Where are economizers located?
outside air hood
What is an enthalpy/temp sensor on an economizer?
tells the controller to open or close damper based on latent/sensible
Economizer:
As outdoor air damper begins to modulate open the return air damper will begin to modulate closed to ensure correct ______ air is maintained
mixed
Some economizers use outdoor air as ____ cooling for the building
free
Set economizer at A,B,C,D settings based on what factors
temperature and relative humidity
Single Duct; Terminal Reheat Distribution:
- economizers can be used to save on _______ costs
- energy efficiency is poor - Induction units were designed for use in exterior rooms of multi story buildings where a high sensible loss occurs, yet at the same time cooling is required in the interior of the building
- cooling
*Single Duct; Terminal Reheat Distribution; Induction Unit:
- Coils: Dual temp ______ (DTW) System
- Low/Med/High (LMH) __ System
Terminology:
- Primary air (______ from main equipment plenum)
- Secondary air (room induced by ________)
- water
- TW
- supply
- primary
An induction box uses the Bernoulli principle to draw room air in and mix with the ______ air
primary