DHC-6 Emergency Memory Items Flashcards
Engine Fire (Ground)
Come to a stop
Park brake - ON
Fire bell - MUTE
Power levers - IDLE
Prop levers - FEATHER
Fuel levers - OFF
Emergency shut off (affected) - OFF
Fire pull handle (affected) - PULL
Boost pump (affected) - OFF/AS REQ
EVACUATE - safest means possible
Engine Fire (Air)
Fire bell - MUTE
Prop & Power - AS REQ
Power (affected) - RETARD 10PSI
Prop (affected) - FEATHER
Fuel lever (affected) - OFF
Emerg shut off (affected) - OFF
Fire pull handle (affected) - PULL
Boost pump (affected) - OFF
Engine Failure Prior to V1
Powers - IDLE
Brakes - MAX
Reverse - AS REQ to maintain direction
Engine Failure After V1 (w Autofeather)
Prop & Powers - MAX
Flap - FLAP 10°
Prop (affected engine) - CONFRIM AUTO FEATHER
At sufficient altitude:
Power (affected) - RETARD 10PSI
Prop (affected) - FEATHER
Fuel lever (affected) - OFF
Engine Failure After V1 (Autofeather Inop)
Prop & Powers - MAX
Power (affected) - RETARD 10PSI
Prop (affected) - FEATHER
Fuel lever (affected) - OFF
Engine Shutdown in Flight
Prop & Powers - AS REQ
Power (affected) - RETARD 10PSI
Prop (affected) - FEATHER
Fuel lever (affected) - OFF
Uncommanded Feather
Prop & Power (unaffected) - MAX
Power (affected) - IDLE
Propeller Reversal (no blade latches)
Affected engine - SHUT DOWN
OEI Missed Approach (Flap 10°)
Speed >80kt with flap 10 or less
Prop & Powers - MAX
Flap - FLAP 10°
Confirm attitude - 80kt
Trim as req
Clearing an Engine/Engine Fire During Start
Ignition CB (clearing only) - PULL
Fuel lever - OFF
Power lever - IDLE
Start switch - HOLD TO MOTOR 10 SEC
If Fire Continues:
Fuel levers - OFF
Fuel emerg shutoff (affected) - OFF
Boost pump - OFF
Fire pull handle (affected) - PULL
Starter Limitations
First use:
25 sec on = 1 min off
Second use:
25 sec on = 1 min off
Third use:
25 sec on = 30 min off
No light-up during start
Fuel lever (affected) - OFF
Starter - MOTOR 10 SEC
Hot Start
Fuel lever (affected) - OFF
Starter - MOTOR 10 SEC
Low Oil Pressure After Start
Shut down affected engine as per shut down
Gen Light Fails To Illuminate After Start (Ground)
Gen switch (affected) - OFF
If Gen Light still doesn’t Illuminate:
Bus tie switch - OPEN
Master switch - OFF
Shut down