Device Based Therapy Flashcards
1
Q
CARE-HF (2005)
A
CRT on M&M
- Class III or IV, LV dysfxn, QRS >150 or 120-149+echo dyssinchfony
- Decreased Death/Hosp for CV
- Better echo parameters, QOL
2
Q
CHAMPION (2011)
A
CARDIOMEMS
- NYHA III, both rEF+pEF
- Decreased readmissions, need DAPT 1m or A/c.
3
Q
COMPANION (2004)
A
CRT w/wo ICD CII-IV, ICM+NICM
- 40% dec CRT-D vs CRT
4
Q
DANISH (2016)
A
Defib in NICM
- EF<35%
- No difference in Primary, Death
- Decrease in SCD
5
Q
DINAMIT (2004)
A
ICD 6-40d post MI (prophylactic)
- No diff in mortality
- Inc non-arryth death vs dec arrythmic death
6
Q
MADIT CRT (2009)
A
CRT-D HFrEF
- II-III, ICM+NICM, QTS>130,
- Dec comp death/HF events
- DEC HF events, no diff death
7
Q
MADIT 2 (2002)
A
Proph ICD for MI+rEF
- Dec mortality
8
Q
SCD-HEFT
A
AMIO vs ICD EF<35%, CII-CIV
- Mortal dec in ICD
- ONLY TRIAL INCLUDING NICM
9
Q
CardioMEMS Post approval
A
58% reduction in HFH, & a 28% reduction rate in all cause hospitalizatioin at 1 year.
10
Q
MUST
A
ICM ef<40% and NSVT
EPS guided study to ICD+AAD
IMPROVED CARDIAC ARREST+Arryrhmic death
No
11
Q
MADIT 1
A
ICM, hfref <35%, documented NSVT!!
Improved mortal