Design Guidelines From NBCP Flashcards
Section 708 of the NBCP
Minimum Requirements for Group A Dwellings
Footings shall be of sufficient size and strength to support the load of the dwelling and shall be at least
250 mm thick and 600 mm below the surface of the ground
The live load of the first floor shall be at least
200 kilograms per square meter (1.96 KN per sq.m.)
The live load of the second floor shall be at least
150 kilograms per square meter (1.47 KN per sq.m.)
The wind load for roofs for vertical projection shall be at least
120 kilograms per square meter (1.18 KN per sq.m.)
Minimum width of stairs
750 mm
Minimum rise of stairs
200 mm
Minimum run of stairs
200 mm
All electrical installation shall conform to the requirements of the
Philippine Electrical Code
Mechanical systems and/or equipment installation shall be
subject to the requirement of the
Philippine Mechanical Engineering Code
Section 805 of the NBCP
Ceiling Heights
Minimum ceiling height of habitable rooms with natural ventilation
2.7 m
Minimum ceiling height of habitable rooms provided with artificial ventilation
2.4 m
Minimum ceiling height of habitable rooms provided with artificial ventilation for more than one storey of the first storey
2.7 m
Minimum ceiling height of habitable rooms provided with artificial ventilation for more than one storey of the second storey
2.4 m