deck_7256652 Flashcards

1
Q

LOX Card (TMU-27/M) Service Pressure?Reference: (MPC 121401.0) P.5

A

40 (+/- 5) psiClose service valve when steady stream of LOX flows from purge adapter/overboard vent.

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
2
Q

LOX Servicing using TMU-27/MReference: (MPC 121401.0) P.4

A

NOTE: If oxygen system has been empty for more than 2 hours and system pressure depleted, O2 system SHALL be purged.-Front of cart(tow hitch end) is facing towards the aft end of aircraft.- Control panel positioned perpendicular to servicing port.- service hose free of bends/kinks.

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
3
Q

Parking/Storage of LOX Cart?Reference: (MPC 121401.0) P.3

A

25’ - Structure w/fire resistant or non-combustible50’ - Structure w/combustion or smoking area75’ - Aircraft parked/fueling and defueling areaNOTE: LOX boil-off during storage can be considerably reduced if storage tank is placed so that the rear end is higher than the front end, thus, in effect, elevating the piping.

How well did you know this?
1
Not at all
2
3
4
5
Perfectly