DC Flashcards
What’s involved in a class A fire ?
Solids ( wood products , paper and fibrous materials)
What’s the recommended extinguishing agent for class alpha fire ?
Water
What’s involved in a class bravo fire ?
Flammable and combustible liquids
What’s the recommended extinguishing agent for class bravo fire ?
Afff
What’s involved in a class Charlie fire
Energize electrics
What’s the recommended extinguishing agent for class Charlie fires
CO2
What’s the most effective tactic to handle a class Charlie fire
D energize and handle as a class Alpha fire
What is involved in a class Delta fire
Combustible metals
What’s the recommended extinguishing agent for class delta fires
Water (fog pattern)
What’s the chemical name for AFFF
Aqueous film forming foam
What’s the chemical name for CO2
Carbon dioxide
What is the chemical name for Halon 1301
Bromotrifluoromethane
What is the chemical name for PKP
Potassium bicarbonate
What is the chemical name for APC
Aqueous Potassium carbonate
What is the effective range of the 18 and 27 pound portable PKP extinguishers
19 feet and 21 feet
What is the minimum discharge time for the 18 and 27 pound PKP extinguisher
10 seconds and 11 seconds
What is the affective range of a 15 pound CO2 portable extinguisher
4 to 6 feet
What is the minimum discharge time for the 15 pound CO2 portable extinguisher
40 seconds
What is the discharge time of an AFFF fire extinguisher
55 to 65 seconds
What is the effective range for an AFFF fire extinguisher
15 feet and decreasing
What is active de-smoking
Removing smoke and heat from the smoke control zone while fighting the fire
What are the four parts of overhaul
Check for hotspots,
Desmoke
Dewater
Atmospheric test
What does NFTI for
Nabel firefighters thermal imager
At what temperature does halon 1301 decompose at
900°F
What are the products formed when halon 1301 decomposes
Hydrogen fluoride and hydrogen bromide
How long will the NFTI Rechargeable battery last one fully charged
4.85 hours
What are EEBD used for
Provide a limited amount of breathable oxygen to evacuate personnel
When is an indirect attacked used
When the fire is fully develop/space is fully involved hi he high-volume smoke and team leader chooses to
What is the responsibility of the reflash watch
Observes the area to ensure that no new fires break out
And Oceana EEBD provides a maximum of how many minutes of oxygen for skate purposes
10 minutes
How many batteries and what kind are used for the NFTI battery pack
10 and AA
How many CO2 flooding systems are on board
Eight
Where are the CO2 flooding systems located
- Five flammable hazmat store rooms we need repair berthings
- One paint issue
- One rewind shop
- One below 11A HT shop
What are the four methods to light off the APC system
Fusible link (350degrees) , APC cylinder, pressure release control box, and remote control box
What type of fireman system do we have on board
Horizontal loop
What circuit is used for damage control and stability
2JZ
What spaces are protected by halon
Fire room, engine room, EDG., pump rooms one and two
How many halon Bottles are in each of the following spaces
- Pump room one
- Pump room two
- EDG
- Fire room
- Engine room
2 2 4 15 20
What are the two sizes of metal shoring
3 to 5 feet and 6 to 11 feet
How many pounds does 3 to 5 feet metal shoring hold
20 K pounds Compacted and 12 K pounds extended
How many pounds of those 6 to 11 feet metal shoring hold
20 K pounds compacted and 6K extended