You are configuring a large number of ports that require the same parameters. What feature is most practical for simplifying the configuration process?
A. Session Manager
B. Port Profiles
C. Port Macros
D Configuration Synchronization
You are configuring a large number of ports that require the same parameters. What feature is most practical for simplifying the configuration process?
B. Port Profiles
What characteristics regarding FET transceiver characteristics are true? (choose 3)
A. FET transceivers can be used to connect a Nexus 2000 to a Nexus 5000 chassis, and to connect a Nexus 2000 to a Nexus 7000 chassis.
B. FET transceivers use a copper transport medium to reduce costs associated with cabling and power.
C. FET transceivers are compatible with SR transceivers.
D. Distances of 30m to 100m are supported.
E. FET transceivers can be used between any platforms (Nexus or Catalyst) as long as the specified distance limitations are not exceeded.
F. FET transceivers are only supported on Nexus 22xx models.
What characteristics regarding FET transceiver characteristics are true? (choose 3)
A. FET transceivers can be used to connect a Nexus 2000 to a Nexus 5000 chassis, and to connect a Nexus 2000 to a Nexus 7000 chassis.
D. Distances of 30m to 100m are supported.
F. FET transceivers are only supported on Nexus 22xx models.
Cisco FET-10G Fabric Extender Transceiver support link lengths up to 100m on laser-optimized OM3 or OM4 multimode fiber. It is supported on fabric links only from a Nexus 22xx to a Cisco parent switch.
http://www.cisco.com/en/US/prod/collateral/switches/ps9441/ps10110/data_sheet_c78-507093.html
B. FET transceivers use a copper transport medium to reduce costs associated with cabling and power. > No, multimode fiber optic cable used.
C. FET transceivers are compatible with SR transceivers. > No, must be connected to another FET.
E. FET transceivers can be used between any platforms (Nexus or Catalyst) as long as the specified distance limitations are not exceeded. > No, only from N2k to parent switch.
A customer is working with a service provider when planning to deploy OTV between two data centers. The customer does not know how the service providers network is configured. What should the customer do to optimize the new OTV solution?
A. The customer doesn’t need to do anything, OTV works transparently over service provider networks.
B. Reduce the MTU on the OTV VLANs to 1,458 to accommodate for the additional 42 bytes of overhead.
C. Increase the MTU on the Join interface(s) to enable jumbo frames.
D. Reduce the MTU on the OTV VLANs to 1,436 to accommodate for the additional 64 bytes of overhead.
A customer is working with a service provider when planning to deploy OTV between two data centers. The customer does not know how the service providers network is configured. What should the customer do to optimize the new OTV solution?
B. Reduce the MTU on the OTV VLANs to 1,458 to accommodate for the additional 42 bytes of overhead. > 14-byte Ethernet header, 20-byte IP header, and 8-byte OTV shim.
OTV verification - show Mac-address-table should show remote endpoints.
The OTV uplink physical interface just has IP address, routing protocol enabled, and IGMP configured. The overlay interface has the config, plus extended VLANs may require MTU lowered 42 bytes for OTV overhead.
Site VLAN is for local communication between OTV edge devices.
Need PIM enabled on interface? No, only IGMP.
When configuring OTV on the Nexus 7000, PIM should be enabled on the “join interface” on the OTV edge device.
A. TRUE
B. FALSE
When configuring OTV on the Nexus 7000, PIM should be enabled on the “join interface” on the OTV edge device.
B. FALSE > The OTV edge device acts as a muliticast endpoint, so should have IGMP configured, but not PIM.
What protocol is not supported on the Nexus 2000 models that support protocol offload?
A. LaCP B. CDP C. IGMP D. LLDP E. DCBX
What protocol is not supported on the Nexus 2000 models that support protocol offload?
C. IGMP
Offload is supported with LACP, CDP, LLDP, and DCBX.
http://www.cisco.com/en/US/docs/switches/datacenter/nexus2000/sw/configuration/guide/Cisco_Nexus_2000_Series_Fabric_Extender_Software_Configuration_Guide_Release_4_2_chapter2.html#con_1046083
Nexus 5000 expansion modules are interchangeable between the Nexus 50xx and 55xx platforms to provide investment protection.
A. TRUE
B. FALSE
Nexus 5000 expansion modules are interchangeable between the Nexus 50xx and 55xx platforms to provide investment protection.
B. FALSE > 55xx use Generic Expansion Module (GEM) 2 which do not work in 5010/5020.
What type of network adapter is required to enable FCoE on an end host (IE: Server)?
A. 10 G Ethernet B. 1G Ethernet C. 1 Gigabit CNA D. 10 Gigabit CNA E. HBA
What type of network adapter is required to enable FCoE on an end host (IE: Server)?
D. 10 Gigabit CNA
What protocol is used to exchange FCoE/QoS configuration information between an FCoE enabled Nexus and an end host (IE: Server)?
A. CDPv1 B. CDPv2 C. LLDP D. VTP E. 802.1Q
What protocol is used to exchange FCoE/QoS configuration information between an FCoE enabled Nexus and an end host (IE: Server)?
C. LLDP - link layer distribution protocol is used by data center exchange protocol (DCBX)
Which of the following platforms support FCoE at FCS (First Commercial Shipment)?
A. Nexus 2148T B. Nexus 4001 C. Nexus 5010 D. Nexus 5020 E. Nexus 7010 F. Nexus 7018
Which of the following platforms support FCoE at FCS (First Commercial Shipment)?
B. Nexus 4001
Enabling fibre channel features on a Nexus 5000 requires an additional license to be installed per chassis.
A. TRUE
B. FALSE
Enabling fibre channel features on a Nexus 5000 requires an additional license to be installed per chassis.
A. TRUE > requires the Storage Protocol Services license
What type of switching is performed in the Nexus 4001?
A. Cut-Through
B. Store-and-Forward
C. Hybrid
What type of switching is performed in the Nexus 4001?
A. Cut-Through
The Nexus product line is a direct replacement for the Catalyst product line.
A. TRUE
B. FALSE
The Nexus product line is a direct replacement for the Catalyst product line.
B. FALSE
How long can a system or fabric fan tray be removed from a Nexus 7000 chassis before the system shuts down?
A. 120 Seconds
B. 180 Seconds
C. 300 Seconds
D. The system will continue to operate as long the temperature is within an acceptable operating range
How long can a system or fabric fan tray be removed from a Nexus 7000 chassis before the system shuts down?
B. 180 Seconds
The expansion slot(s) on the Nexus 5010 and 5020 chassis support OIR.
A. TRUE
B. FALSE
The expansion slot(s) on the Nexus 5010 and 5020 chassis support OIR.
A. TRUE
What is the default power redundancy mode for a Nexus 7000 chassis?
A. Combined B. Power Supply Redundancy (N+1) C. Power Supply and Input Source Redundancy (Full Redundancy) D. Input Source Redundancy (GRID) E. No Redundancy
What is the default power redundancy mode for a Nexus 7000 chassis?
C. Power Supply and Input Source Redundancy (Full Redundancy) > System default redundancy mode; guards against failure of either one power supply or one AC grid, and power available is the minimum power from the input source and power supply redundancy.
http://www.cisco.com/en/US/prod/collateral/switches/ps9441/ps9402/ps9512/Data_Sheet_C78-437761_ps9402_Products_Data_Sheet.html
The Nexus 7000 supports ISSU, which enables a software upgrade without disrupting the data forwarding plane (0 packet loss).
A. TRUE
B. FALSE
The Nexus 7000 supports ISSU, which enables a software upgrade without disrupting the data forwarding plane (0 packet loss).
A. TRUE
http://www.cisco.com/en/US/docs/switches/datacenter/sw/5_x/nx-os/high_availability/configuration/guide/ha_issu.html
What is the maximum number of ports on the Nexus 2148T or 2248TP that can be configured for network (fabric) connectivity?
A. 1
B. 2
C. 4
D. 48
What is the maximum number of ports on the Nexus 2148T or 2248TP that can be configured for network (fabric) connectivity?
C. 4 > uplinks
What is the maximum number of Nexus 4001 switches that can be installed in a server chassis?
A. 1 B. 2 C. 4 D. 6 E. 8
What is the maximum number of Nexus 4001 switches that can be installed in a server chassis?
C. 4 > switches in a chassis
http://www.cisco.com/en/US/prod/collateral/switches/ps9441/ps10596/ps10642/data_sheet_c78-560881_ps10596_Products_Data_Sheet.html
What is the PPS performance for the first generation forwarding engine (M1) in the Nexus 7000 Ethernet modules for IPv4 and IPv6? (Answer Format = IPv4 / IPv6)
A. 48 Mpps / 24 Mpps
B. 60 Mpps / 30 Mpps
C. 60 Mpps / 60 Mpps
D. 120 Mpps / 60 Mpps
What is the PPS performance for the first generation forwarding engine (M1) in the Nexus 7000 Ethernet modules for IPv4 and IPv6? (Answer Format = IPv4 / IPv6)
B. 60 Mpps / 30 Mpps
*D. 120 Mpps of L2 or IPv4 unicast forwarding / 60 Mpps IPv6 unicast forwarding with dual M1-XL forwarding engines
What optic type is supported in the Nexus 7000 32 port 10GE module (N7K-M132XP-12)?
A. X2 B. SFP C. XFP D. SFP+ E. XENPAK
What optic type is supported in the Nexus 7000 32 port 10GE module (N7K-M132XP-12)?
D. SFP+
How many Nexus 2000’s (FEX) can be connected to a pair of Nexus 5010 or 5020 chassis using vPC?
A. 12
B. 24
C. 20
D. 40
How many Nexus 2000’s (FEX) can be connected to a pair of Nexus 5010 or 5020 chassis using vPC?
A. 12
The NX-OS uses interface CLI commands to assign IP networks to an IGP routing instance.
A. TRUE
B. FALSE
The NX-OS uses interface CLI commands to assign IP networks to an IGP routing instance.
A. TRUE
How many VRF instances are supported per Nexus 7000 VDC?
A. 100
B. 200
C. 800
D. 8192
How many VRF instances are supported per Nexus 7000 VDC?
B. 200 > 5.2 supports 1000 VRFs
http://www.google.com/url?sa=t&rct=j&q=&esrc=s&source=web&cd=1&ved=0CCEQFjAA&url=http%3A%2F%2Fwww.cisco.com%2Fen%2FUS%2Fdocs%2Fswitches%2Fdatacenter%2Fsw%2Fverified_scalability%2Fb_Cisco_Nexus_7000_Series_NXOS_Verified_Scalability_Guide.pdf&ei=o9OWULmQAYbI9gTOhICQAw&usg=AFQjCNH_cvuhh7dQy1ehvqHPUp8VKuIqMg
How many OSPF processes are supported per VDC?
A. 1 B. 4 C. 8 D. 16 E. 32
How many OSPF processes are supported per VDC?
D. 16 processes per VDC supported with 6.1, but also 16 processes per system. 4 processes per VDC prior to 6.1, with 16 processes per system.
What Spanning-Tree Protocols (STPs) are configurable on the Nexus 7000/5000/4000 platforms?
A. 802.1d
B. MST
C. PVST
D. Rapid-PVST+
What Spanning-Tree Protocols (STPs) are configurable on the Nexus 7000/5000/4000 platforms?
B. MST
D. Rapid-PVST+
The Nexus vPC feature was designed to use the same unified control plane technology/concepts as the Catalyst 6500 VSS to achieve Multi-Chassis Etherchannel functionality.
A. TRUE
B. FALSE
The Nexus vPC feature was designed to use the same unified control plane technology/concepts as the Catalyst 6500 VSS to achieve Multi-Chassis Etherchannel functionality.
B. FALSE
What is the maximum number of Ethernet interfaces that can be bundled in a static mode or LaCP port-channel on the Nexus 5000 or 5500 chassis?
A. 4
B. 8
C. 16
D. 32
What is the maximum number of Ethernet interfaces that can be bundled in a static mode or LaCP port-channel on the Nexus 5000 or 5500 chassis?
C. 16
Different versions of NX-OS software can run in different VDC’s for maximum scalability and flexibility.
A. TRUE
B. FALSE
Different versions of NX-OS software can run in different VDC’s for maximum scalability and flexibility.
B. FALSE