DAA List of Dominion Codes Flashcards
TD7625GROD*
Pad mount transformer, 25 kVA, 19.9 kV to 120/240 volts
TD76100GROD*
Pad mount transformer, 100 kVA, 7.6 kV to 120/240 volts
TD1925GROD*
Pad mount transformer, 25 kVA, 19.9 kV to 120/240 volts
TD19100GROD*
Pad mount transformer, 100 kVA, 19.9 kV to 120/240 volts
KPTERM10
1 PH TERMINATION NON-ENERGIZED =<1/0
TD1916776*
Pad transformer stepdown deadfront, single phase, 167 kVA, 19 kV to 7.6 kV
TD1950076*
Pad transformer stepdown deadfront, single phase, 500 kVA, 19 kV to 7.6 kV
PDPC1T36BF
Precast box pad for single phase transfomers
FEEDTHRU
200 amp, large interface, 35 kV loadbreak bushings
AR27EBMOVGS
Arrester, 27 kV elbow (for 19 kV circuits)
FCUSLV
Fuse, current limiting, 200 amp, 250V 2 sleeve term., 4/0 al - (Code for 2 each address)
FEEDTHRU2
200 amp, small interface, 15 kV loadbreak bushings
PROTECAP200
Protective Static Cap, 35 kV
PROTECAP15KV
Protective Static Cap, 15 kV
AR10EBMOVTSM
Arrester, 10 kV elbow (for 7.6/7.2 kV circuits)
FI300UGL
Fault Indicator, 300 amp trip, 1 phase transformers (every fifth transformer)
KCPBLTERM10
Termination of primary cable into existing transformer pad
CND4S490D36
PVC Schedule 40 4” elbow 90° 36” radius
KOPEXISTTRF
Install Open Point into existing transformer pad
KCBLREARR
Use when splicing new primary into existing primary between devices
KFIEXISTTRF
Installation of fault indicator into existing transformer pad
TME10J3
Terminator Elbow, 21.1/36.6kV for 1/0 al., jacketed, 345 mil, cable
SD1TPVE
Single Phase Tap Switch
TME10J3
Terminator Elbow, 21.1/36.6kV for 1/0 al., jacketed, 345 mil, cable (quantity of 4 need)
FI300CRUG
Fault indicator, 300 amp trip, u.g. 1 ph. 1/0 cable -
SECPED
Secondary Pedestal
KTERMPED
Secondary termination non-energized =<1/0
FCU2SPD
Fuse, c.l., 200 amp, 250V, two 1-hole spade term. For pedestal - (Code for 2 each address)
DTC27GROD*
Dummy transformer cabinet, (27 kV elbow for 19 kV circuits)(10 kV elbow for 7.6/7.2 kV circuits)
KPTERM10
1 PH TERMINATION NON-ENERGIZED =<1/0
FI300CRUG
Fault indicator, 300 amp trip, u.g. 1 phase 1/0 cable - Dummy transformers
GROD4CUUG (15)
1-4 Ft. Copper Rod & Coupling
GRODCUUGF
Fixed Items Copper Rod, Each Location
KGRDROD
Labor code to install ground rods
GNDKITLC
GROUNDING KIT FOR SPLICE PITS
KTUNNEL2
GUIDE DRILL EXCAVATE 2 IN TUNNEL
KTUNNEL4
GUIDE DRILL EXCAVATE 4 IN TUNNEL
KTUNNEL6
GUIDE DRILL EXCAVATE 6 IN TUNNEL
KROCKDRL4
ROCK GUIDE DRILL (INCLUDE FOOTAGE’)
CND2SPOOL
HDPE 2”, Schedule 40, Conduit - (1/0, 4/0, #8)
CND4SPOOL
HDPE 4”, Schedule 40, Conduit - (750)
CND3SPOOL
HDPE 3”, Schedule 40, Conduit - (500)
KCND2TUNNEL
PULL 2” CONDUIT THROUGH TUNNEL
KCND3TUNNEL
PULL 3” CONDUIT THROUGH TUNNEL
KCND4TUNNEL
PULL 4” CONDUIT THROUGH TUNNEL
U10J3TUNOO
1/0 primary, guide drill from pole to pole
U10J3TUNOP
1/0 primary, guide drill from pole to pad
U10J3TUNPP
1/0 primary, guide drill from pad to pad
U10J3TUNOS
1/0 primary, guide drill from pole to splice
U10J3TUNPS
1/0 primary, guide drill from pad to stub up
U10J3TUNSP
1/0 primary, guide drill from splice to pad
U10J3TUNSS
1/0 primary, guide drill from splice to splice
U10J3TUNSP
1/0 primary, guide drill from splice to pad (OPEN/CLOSE Holes built into MU)
KPSPLICE10
1/0 SPLICE LABOR
SPL10J3
1/0 SPLICE KIT
KCBLSPK
DE-ENERGING EXISTING 1/0 PRIMARY LABOR (Test before splicing new into existing for safety)
KXHOLEAO
OPEN STANDARD SPLICE PIT 6’X4’X4’
KXHOLEAC
CLOSE STANDARD SPLICE PIT 6’X4’X4’
KPSPLICE10
1/0 SPLICE LABOR
SPL10J3
1/0 SPLICE KIT
KPPOTP
VDOT ROAD CROSSING ( POTHOLE TO LOCATE UTILITIES)
USGD50PAPD
UG 500 Secondary, guide drill from transformer to pedestal
USGD50PAOH
UG 500 Secondary, guide drill from transformer to pole
USGD50PDPD
UG 500 Secondary, guide drill from pedestal to pedestal (Not Standard Practice)
USGD75PAPD
UG 750 Secondary, guide drill from transformer to pedestal
USGD75PDPD
UG 750 Secondary, guide drill from pedestal to pedestal
BUSPLATE (3)
Secondary Busplate for 1P Transformers, 8 hole plate
LP50GD
500 service lateral guide drill from pedestal to meter w/ 3” riser
LP50GDPDSP
500 service lateral guide drill from pedestal to splice
LT50GD
500 service lateral guide drill from transformer to meter
LT50GDSP
500 service lateral guide drill from transformer to splice
LT40GD
4/0 service lateral guide drill from transformer to meter or jbox
LT40GDSP
4/0 service lateral guide drill from transformer to splice
LP40GD
4/0 service lateral guide drill from pedestal to meter (or jbox) w/ 2” riser
LP40GDPDSP
4/0 service lateral guide drill from pedestal to splice
LP40GDPDST
4/0 service lateral guide drill from pedestal to stub up
SEC2AL
2 Aluminum Entrance Cable
SEC20AL
2/0 Aluminum Entrance Cable, 100 amp meters (removal only)
SEC40AL
4/0 Aluminum Entrance Cable, 200 amp meters
LT50GD40SP
500 splice into 4/0 service lateral guide drill from Tranformer
USGD40PAOH
UG 4/0 Secondary, guide drill from transformer to pole
USGD50PAOH
UG 500 Secondary, guide drill from transformer to pole
USGD40PDOH
UG 4/0 Secondary, guide drill from pedestal to pole
USGD50PDOH
UG 500 Secondary, guide drill from pedestal to pole
SVCBRKWAY2
Service line breakaway
LT40GD
4/0 service lateral guide drill from transformer to meter or jbox
CND2S4
PVC Schedule 40 2”
KHT24
HAND TRENCH/BACKFILL 24 IN (include footage’)
KCNDTRNC* (2 OR 4)
PLACE CONDUIT IN TRENCH 2 IN OR 4 IN (include footage’)
KCBLTRNC* (2 OR 4)
TIEING EXISTING SVC DIRECTLY INTO TRANSFORMER
CND*S490D24 (2 OR 3)
PVC Schedule 40 2” elbow 90° 24” radius (2 or 3, Conduit size)
USL8DCUGDPAOH
8 service guide drill from transformer to street light
USL8DCUGDPDOH
8 service guide drill from pedestal to street light
USL8DCUGDPOPO
8 service guide drill from street light pole to street light pole
M1LBOX1LH
Junction box, left hand, 100 amp
M1LBOX2LHA
Junction box, left hand, 200 amp, stud terminal
M1LBOX1RH
Junction box, right hand, 100 amp
M1LBOX2RHA
Junction box, right hand, 200 amp, stud terminal
M1LBOX2LHB
Junction box, left hand, 200 amp, lay-in terminal
M1HBOX100
Junction box, Horizontal, 100 amp
M1VBOX100
Junction box, Vertical, 100 amp
M1HBOX200
Junction box, Horizontal, 200 amp
M1VBOX200
Junction box, Vertical, 200 amp
KTERMDP* (4 OR 5)
Labor to install service lateral into bottom of meter (when J Box is not used)
KCBLSPL* (4 OR 5)
Labor to splice existing service lateral (when J Box is not used)
KMETERCHK
Labor to check meter voltage (use with existing SVC splice, when leaving SVC OH, and when J Box is not used)
LUBE3GAL
1 case (6-1/2 gallon bags) of cable lubrication
LUBE2QT
½ gallon bag of cable lubrication
Calculations for Lube
Distance (x) Conduit Size (x) 0.0015 = # of Gallons (Conduit Size 2” or 3”)
P355
35 ft., class 5 wood pole
P306
30 ft., class 6 wood pole
P404
40 ft., class 4 wood pole
KSEED
TRANSFORMER = 12’, PEDESTAL = 10’, PRIMARY SPLICE = 12’, SECONDERY SPLICE = 6’, HAND DIGGING = 1’ (for every square foot)
P453
45 ft., class 3 wood pole
P502
50 ft., class 2 wood pole
P551
55 ft., class 1 wood pole
P306
Pole 30’ Class 6
P404
Pole 40’ Class 4
P453
Pole 45’ Class 3
P355
Pole 35’ Class 5
P502
7’
P551
Pole 55’ Class 1
VR1
Vertical ridge pin, tangent, single phase (Removal Only)
VA1
Vertical angle, 6” porcelain insulators, single phase,10°-60° (Removal Only)
VRD1
Vertical ridge pin double, tangent, single phase (Removal Only)
VRDP1
Vertical ridge double post insulator, single phase
VRP1
Vertical ridge post, tangent, single phase
VAP1
Vertical angle, polymer insulator, single phase, 10°-60°
FU3
Flat underbuild, 3 conductors, single arm
FR3
Flat ridge pin 3 conductors, single arm
FRP3
Flat ridge, post insulators, 3 conductors, single arm
FUP3
Flat, underbuild, post insulators, 3 conductors, single arm
PEXT
Post Top Extension
FP3
Flat, post insulators, 3 conductors, single arm
XWB
Crossarm, single, wood brace, 8’
XWBG
Crossarm, single, wood brace & gain, 8’
X10WBG
Crossarm, single, wood brace & gain, 10’
X10WB
Crossarm, single, wood brace, single, 10’
X10DEFGLD
Crossarm, deadend, fiberglass, 10’ Light Duty (Standard Install)
XFB
Crossarm, single, flat brace, 8’
XDWB
Crossarm, double, wood brace, 8’
XFBG
Crossarm, single, flat brace & gain, 8
XDFB
Crossarm, double, wood brace, 8’
TM110J3V
Terminal, single phase, 1/0 cable on vertical overhead line
TM110J3F
Terminal, single phase, 1/0- cable on flat overhead line
U10J3
1/0 jacketed, 35 kV primary cable from terminal to ground (Include footage)(Removal Only)
AR27OHMOVP
“Arrester 27 kV, metal oxide type, polymer
For general line arresters, capacitors, transformers, and scout arresters with
a wye primary connection on 19.9/ 34.5 kV circuits”
AR27TMMOVP
“Arrester 27 kV, metal oxide type, polymer, riser type
For terminal poles, recloser, sectionalizers, voltage regulators and primary
metering and substation getaway applications with wye primary connections on
34.5/ 19.9 kV.”
AR10OHMOVP
“Arrester 10 kV, metal oxide type polymer. For all Wye primary connected 7.2/ 12.5
kv and 7.6/ 13.2 kv distribution applications.For terminal poles, recloser, sectionalizers, voltage regulators and primary metering.”
T76167TV
Single Phase OH Transformer vertical, 167 kVA, primary voltage 7.6 kV
LAF1
Arrester, flat, 1 phase (Install Only)
T1925TV
Single Phase OH Transformer vertical, 25 kVA, primary voltage 19.9 kV
T19100TV
Single Phase OH Transformer vertical, 100 kVA, primary voltage 19.9 kV
T7625TV
Single Phase OH Transformer vertical, 25 kVA, primary voltage 7.6 kV
T7225TV
Single Phase OH Transformer vertical, 25 kVA, primary voltage 7.2 kV
VDEP1
Vertical deadend, polymer insulator, single phase
T72100TV
Single Phase OH Transformer vertical, 100 kVA, primary voltage 7.2 kV
VDEP1V
Vertical deadend, polymer insulator, single phase tap
VDEP1VCO
Vertical deadend, polymer insulator, single phase w/cutout
VDEP1EXT
Vertical deadend, polymer insulator, single phase, extension link
CO27LINE1
Cutout, 27 kV, standard, 100 amp for line
VDDEP1S
Vertical double deadend, polymer insulator, single phase, tangent
DESHOE* (2 or 10)
Dead end clamp for 1/0
CO27LDLINE1
Cutout, 27 kV, loadbreak, 100 amp for line
CO27LINE2
Cutout, 27 kV, standard, 200 amp for line
CO27SBLINE3
Cutout, 27 kV, solid blade, 300 amp for line
S1
Secondary 1 conductor, clevis & insulator, angle (0° - 30°) or tangent (Continuous Neutral)
F622100
100 amp ’QA’
CO27LDLINE2
Cutout, 27 kV, loadbreak, 200 amp for line
F622200
200 amp ’QA’
F622025
25 amp ’QA’
SDDE1
Secondary double deadend 1 conductor, clevis & insulator
SDE1
Secondary deadend 1 conductor, clevis & insulator
SDDE1FLT
Secondary double deadend 1 conductor floating
SDDE190
Sec. double deadend 1 conductor, clevis & insulator, 30° - 90°
STDE
Secondary triplex, deadend
SDDESC
Neutral double deadend with strain clamp, 4/0 and larger
STDDE
Secondary triplex, double deadend
SVENT100F
Service entrance cable, overhead, 100 amp (Removal Only)
SVC2T
Service drop #2 triplex
SVC40T
Service drop #4/0 triplex
SEC2AL
2” Entry Cable
SVENT200F
Service entrance cable, overhead, 200 amp (Removal Only)
SEC40AL
4/0 Entry Cable
SEC20AL
2/0 Entry Cable
GI516
5/16” insulated guy, single eye pole plate
GI716
7/16” insulated guy, single eye pole plate
G516
5/16” uninsulated down guy
G716
7/16” uninsulated down guy
GSP516
Guy, uninsulated span, 5/16”
GISP516
Guy, insulated span, 5/16”
GSP716
Guy, uninsulated span, 7/16”
GISP716
Guy, insulated span, 7/16”
GG
Guy, guard
GISW516
Guy, insulated sidewalk 5/16”
GGM
Guy guard, multiple
ANC8PIHS
Anchor, 8” power installed high strength tapped for 1” x 7’ rod, twin eye
ANC10PIHS
Anchor, 10” power installed high strength tapped for 1” x 7’ rod, twin eye
ANC12PIHS
Anchor, 12” power installed high strength tapped for 1” x 7’ rod, twin eye
PGX
Perch guard (PVC) for single crossarm
ANCH14PIHS
Anchor, 14” power installed high strength tapped for 1” x 7’ rod, twin eye
WLGTX
Wildlife guard for OH Transformers
RSP2
Riser Shield, polyethylene 2”
RSP6
Riser Shield, polyethylene 6”
GROD4CUOH
1-4 ft. copper rod & coupling - (15) EACH
GRODCUOHF
Fixed items copper rod, each location
RSP4
Riser Shield, polyethylene 4”
CND2S4
PVC Schedule 40, 2”
CND2GV
Schedule 40, 2”
GDMOLD
GROUNDING MOLDING
SUGPOLEBANDR
Reflective red pole band 1-3/8” x 36” / (42333009)
LOHSC
Luminaire overhead secondary and grounding connections
BKTUS30IN1
Bracket, upsweep 30 in., galv. 1-1/4 in. O.D. pipe, for use on wood poles
POLECAP7
Pole Cap 7-1/2” / (51630700)
POLECAP10
Pole Cap 10-1/2” / (51631300)
P2CU*
Bare #2 - H.D. str. Copper
GROD6CUOH
1-6 ft. copper rod & coupling - (15) EACH
GROD8CUOH
1-8 ft. copper rod & clamp - (15) EACH
POLECAP8
Pole Cap 8-1/2” / (5160900)
POLECAP9
Pole Cap 9-1/2” / (51631100)
POLECAP6
Pole Cap 6-1/2” / (51630500)
P10AL*
Bare 1/0 - AAAC / ACSR
P2AL*
Bare #2 - AAAC / ACSR
P4CU*
Bare #4 - H.D. solid Copper
TIE2PIN or POST
Primary tie wire for #2 - #6 AAAC / ACSR
TIE10PIN or POST
Primary tie wire for 1/0-1350 AAAC / ACSR
PWIREXFERA
Transfer existing primary into new ridge pin - < 4/0
PWIREXFERB
Transfer existing primary into new ridge pin - > 1/0
N10AL*
Bare 1/0 - AAAC / ACSR
N2AL*
Bare #2 - AAAC / ACSR
N4CU*
Bare #4 - H.D. solid Copper
N2CU*
Bare #2 - H.D. str. Copper
TIE10SPOOL
Neutral tie wire for 1/0 - 1350 AAAC / ACSR
SWIREXFERA
Transfer existing secondary/neutral into new clevis - < / = 1/0
TIE2SPOOL
Neutral tie wire for #2 - #6 AAAC / ACSR
SWIREXFERB
Transfer existing secondary/neutral into new clevis - > 1/0