Control System
BNT-850HE (UF) Control Valve
Regeneration Type
Up Flow
Regeneration Mode
Meter Immediate / Meter Delay / Meter Override / Vacation
Hardness Removal
@ 48 g/L salt dosage
171 g
Hardness Removal
@ 96 g/L salt dosage
232 g
Hardness Removal
@ 192 g/L salt dosage
304 g
Tank Size
08x15 inches
Sand Quantity
/ Kg
Resin Quantity
8 L
Salt Storage Capacity
15 Kg
Rated Service Flow
0.9 m³/hour
Back Wash Flow Rate
5.7 L/min
Water Used Per Regeneration
(@ 96 g/L salt dosage)
32 L
Product Dimension
420x244x555 mm
Carton Size
482x262x680 mm
Container Capacity
660 pieces / 40’’ HQ
Plumbing Connections
3/4’’ or 1’’ Fittings Available
Electrical Requirements
(Input)
110V-120V / 220-240V AC 50/60 Hz
Electrical Requirements
(Output)
12V AC 650mA
Water Supply
Municipal
Water Temperature
4 ~ 43 ºC
Operating Pressure
0.21 ~ 0.86 MPa