CR system Flashcards

0
Q

What type of laser is used in a CR machine

A

A class 3B laser

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
1
Q

What allows for high resolution images with high fidelity across the entire image in a CR machine

A

A flat scan path

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
2
Q

What allows images to be stored in many different file formats while allowing users to adjust, view, print and transfer images all in one application

A

STARRview

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
3
Q

What is known as the differences in the amount of absorbs energy from place to place in the plate (IP)

A

Contrast

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
4
Q

What dictates spatial resolution of an image

A

Scanning process and IP type

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
5
Q

The front screen (lead screen) is not required until energy reaches what KV range

A

150 to 160

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
6
Q

How big of a lead screen should be used for back scatter prevention

A

1/8th inch

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
7
Q

Exposure time should be what

A

As long as practical (without causing saturation)

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
8
Q

All IP’s are what

A

Made of the same type of polyester plastic substrate as modern x-ray films unlike most x-ray films IP’s are all single-sided and the thickness of the sensitive layer is greater than for film emulsion layers

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
9
Q

What is the normal wear out mechanism for IPs

A

Mechanical damage or abrasion

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
10
Q

Blank resolution IP’s are needed for crack detection where blank resolution IP’s can be used for FOD

A

Higher and lower

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
11
Q

The red laser light is focused to a small range of microns what is that range?

A

50-200 microns (50 microns equals .002 inch

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
12
Q

what determines spatial resolution

A

The size of the laser light determines the smallest image features that can be possibly spatially resolved

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
13
Q

What determines the actual image resolution limit

A

The blue emissions spot

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
14
Q

What should the PMT voltage/gain sitting be set to

A

As low as possible without affecting steeple operation of the PMT

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
15
Q

What is the process of changing the electrical signals emitted by the PMT into a visible representation that can be viewed as an image

A

Display conversion

16
Q

The CR system A/E99D-3 is a portable CR system consisting of five major parts what are those parts?

A
Scanner (78 pounds)
 monitor (29 pounds)
 CPU (XX pounds) 
ABR (9.7 pounds) 
imaging plates
17
Q

What are the power for the scanner

A

110 +/- 10 VAC, 50/60Hz or 23 +/- 10 VAC, 50/60Hz,

18
Q

How many shades of gray?

19
Q

What is the resolution of the monitor

A

2048 X 1536

20
Q

How many hard drives

21
Q

What is the maximum output power capacity for the AVR

A

1200 W or 1200 VA

22
Q

What is the nominal output voltage for the AVR

A

110,120, or 127

23
Q

How many outlets Does the AVR have

24
Q

What is the operating temperature of the AVR

25
Q

What are the plate sizes

A

5 x 7, 10 x 12, 14 x 17,

26
Q

What is the temperature range of the imaging plate

A

-40° - +120°F

27
Q

What is the focal spot size of the laser

A

50 microns

28
Q

what keeps the Red light from reaching the photomultiplier tubes (PMT)

A

Blue glass filters

29
Q

What are five tools not intended for Navy or Marine Corps use

A
Density mapper
calibrate gradient 
pipe gradient analysis 
calibrate 5 point sample 
dynamic ranging filter
30
Q

What is the intensity scale the histogram

A

0 to 65,500

31
Q

Up-and-down changes what? Left and right changes what?

A

Window and level respectively

32
Q

The magnifier presents a simple how many times magnification?

33
Q

Process control tests are split into what three types?

A

Display monitor tests
system tests
IP tests