CoP for Non Standard linacs Flashcards
What field do you need to create if your linac can’t make a 10x10 field?
A machine specific reference field
What factors need to be corrected?
The quality index and field size
What are the reference factors for Tomotherapy?
5cm deep, 85cm SSD, phantom width>= field+5cm, backscatter>=5cm.
If a machine is unable to make a large enough field for reference dosimetry what is an alternative?
Make a uniform field out of composite non-uniform fields. This is called a plan class specific reference
What are the requirements of composite fields?
Must ensure the chamber reacts well to composite fields.
Needs to produce a uniform field large enough for reference dosimetry.
For composite fields what term is added to the equation D=RN?
kfc - accounts for difference in chamber response between machine specific reference and plan class specific reference.
For the A1SL chamber in a low gradient field what is the value of kfc?
1