What is the branch pressure of a 2 pipe thermostat

A

0-20 psi

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
2
Q

What control system has ultimate authority

A

Fire alarm

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
3
Q

A pilot duty interrupts the current to the motor directly

A

False

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
4
Q

Two position thermostats are analog

A

False Variable

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
5
Q

Advantage of 3 pipe controller over a 2 pipe controller is

A

Greater capacity and ability to control multiple actuators

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
6
Q

An actuator controls the dampers in an HVAC unit

A

True

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
7
Q

When the high limit trips on a furnace it kills power to what

A

Gas valve

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
8
Q

What is an electronic hygroscopic sensor made of

A

Resistance change polymer
Gold foil grid
Thin film polymer

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
9
Q

In an electronic thermostat the length of time it takes for the control point and the setpoint to equalize is called

A

Deviation

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
10
Q

Only semi hermetic compressors have an oil pump use an oil failure control

A

True

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
11
Q

Mixed air controllers are typically set to

A

50F-60F

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
12
Q

What do OFC protect in the system

A

Compressor

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
13
Q

Why is the crankcase heater energized for the compressor during the shut down period

A

Prevent oil foaming on compressor startup

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
14
Q

What is an acceptable temperature dry bulb setpoint for a change thermostat

A

50F-60F

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
15
Q

In a freezer the fan delay job is to

A

Allow water to freeze on it after a defrost prior to the fans starting up

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
16
Q

Cooling thermostat is reverse or direct acting?

A

Direct

17
Q

Why do low temp refrigeration have oil return issues

A

Low density refrigerant suction vapor doesn’t carry oil with it well

18
Q

Delay on break suits

A

Short cycling

19
Q

For the OFC to operate correctly the crankcase pressure needs to be lower then the oil pump pressure

A

True

20
Q

3 most common sensors

A

Humidity
Pressure
Temp

21
Q

A system without feedback is

A

Open loop