An automatic fire protection system especially automatic sprinklers is the _____________ in many buildings.
The first line of defense
P. 23
______________ management is systematic and included many factors including life safety engineering and administrative controls to protect community resources.
Fire loss
P. 28
Flow of heat from a hot substance to a cold substance
Heat transfer
P. 31
Buildings must have a minimum number of exits based on the expected ________ capacity and classification.
Occupancy
P 35
Type II a requires that structural components to have a _____ hour fire resistance.
1 hour.
P. 47
________ total quantity of combustible material in a compartment. Heat of combustion
________ the maximum amount of heat that can be released if all fuel in consumed. HHR
Varies with heat of combustion of the fuel load.
Fuel load
Fire load
P. 54
The most commonly used test for determining combustibility is _________.
Astm e-136
P. 54
Laboratory testing is the most common method to determine fire resistant. The standard test is the _________ also known as nfpa________.
Astm e-119
Nfpa 251
P 55
Astm 1529
Hydrocarbon pools test
P. 58
Joint systems test.
UL 2079
P. 58
Despite the limited lab testing ______ test is the only standardized test method universally accepted by building codes.
E-119
P. 58
The nfpa _________ test is the most commonly used method to satisfy building codes requirements for structural fire resistance.
Same as e119
P. 60
Load that is steady motionless constant or applied gradually
Static load
P. 70
A _____ load is fixed and _______.
Dead
Quantifiable.
P. 70
________ load that involves motion. Also known as ______
Dynamic load
Shock loading
P. 71
_________ loads that create horizontal motion are the most significant force generated by an earthquake.
Lateral
P. 76
Seismic waves affect some buildings differently than others due to the ______ of the earthquake and each buildings features.
Resonance
P. 76
Structural elements designed to control vibration from resonance.
Damping mechanism
P. 77
Most elevator regulations are based on ____________ safety codes published by the asme.
Asme/ansi 17.1
P. 103
Modern elevator cables are flat ________ Coated steel belts that increase energy efficiency
Polyethylene
P. 104
In very tall buildings express elevators are divided into zones. A zone often includes ____ to ______ consecutive floors.
15 to 20
P. 110
Theaters are required to have ___________ over the stage.
Smoke vents.
P. 124
In cases where utility companies do not allow sprinklers the utility companies may permit ____________ detection systems
Carbon dioxide
P. 128
At a minimum an occupancy should be supported by enough generator service to meet __________ plus the _______ of the occupancy.
Life safety systems
Critical needs
P. 130
Swinging fire doors are available with ratings from ____ to_____.
20 minutes to 3 hours
P. 156
Dimensional lumber is available in lengths from ____ to ____.
8-24 feet