this condensing furnace accessory is powered by 120vac?
condensate pump
A condensate neutralizer is used to lower the PH level of the condensate produced by a natural gas condensing furnace
false
the amount of condensare produced by a 100,000 Btu/hr natural gas condensing furnace in one hour?
one gallon
the typical PH level of the condensate produced by a natural gas condensing furnace is between 2.9 and 4.o
true
a condensate neutralizer is used to —-the PH level of the condensate produced by a natural gas condensing furnace to 5 pH or about before it enters a waste water drain system is?.
raise
this condensing furnace accessory is utilized to pump air conditioning condensate and the condensate produced by the condensing furnace to a deep sink/laundry tub when a floor drain is not located near the condensing furnace?
condensate pump
the position of the condensate pump float safety switch if the condensate pump fails to lower the level of the condensate in the condensate pump reservoir?
in the high active position
the position of the condensate pump float safety switch when there is a norma level of condensate in the condensate pump reservoir is?
closed
the condensate pump—– will prevent 24vac to the thermostat sub-base if the condensate pump fails to lower the level of the condensate in the condensate pump reservor?
float safety switch
the water that we drink has a pH level of 0.7, which is considered neutral of non-acidic?
true
thermostat sub -base wiring and more
1, this automatic reset safety switch would open if the heat exchanger gets too hot?
High limit
2, the color of the conductor connected to the y terminal on the thermostat sub-base?
yellow
3, this temperature activated switch closes on space temperature rise is?
circuit breaker
4, the color of the conductor connected to the o terminal on the thermostat sub-base Is?
orange
5, this manual rest safety switch would open if the flames roll back into the burner box is?
rollout
6, the color of the conductor connected to the B termina on the thermostat sub-base is?
black or brown
7, the color of the conductor connected to the W terminal on the thermostat sub-base Is?
white
8, this 24volt load is energized when the sub-base is switched to fan on is ?
fan relay
9, this 120volt load provides 24volt operational and safety voltage is?
transformer
10, the color of the conductor connected to the R terminal on the thermostat sub-base is ?
red
11, this temperature activated switch closes on space temperature fall is ?
NO normal open temperature switch
12, this electrical component provides overcurrent protection for the transformer is?
fuse
13, the color of the conductor connected to the C terminal on the thermostat sub-base Is?
blue
14, this manual reset safety switch would open if the return air temperature exceeds the manufacture’s return air limit setting is?
auxiliary limit
15, the color of the conductor connected to the G terminal on the thermostat sub-base is ?
green