Cold Water Flashcards
The water Regulations state that the warning pipe in cold water cistern must be?
Sized to be able to cope with flow of water should the inlet valve fail
The vessel used to hold water in storage is refered to as a
Cold Water Storage Cistern
Which British Standard makes recommendation on the minimum size of cold water storage cisterns for a particular property?
BS EN 8558
Where would you find details of the quantity of fittings delivered to site by a plumbers merchant?
In the delivery note
Which of the following types of cold water system would normally be used in a dwelling which has high incoming water?
Direct
Which one of the following valves contains a valve seat (orifice) which you can change according to the available water pressure in the supply pipe?
A float operated valve
What us the minimum recommended clip spacing for a 22mm vertical copper pipe?
2400mm
To overcome the problems of noise created by high pressure mains in storage cisterns, the float operated valve is replaced with
Equilibrium float valve
The system of pipework which is to be found buried beneath the roads and streets which is used to convey water is referred to as the
Water mains
A float operated valve will respond to the rise and fall of the ……………… in the storage cistern
Level of the water
The special property of the ferrule is that it can be inserted into the water main using a clamp on chamber…
Without having to turn off and drain down the water main
The boundary stop tap is normally found
Just outside the perimeter of the property which it feeds
Direct cold water systems in areas with very high mains pressure are prone to giving off noise when the water flows. This is referred to as
Velocity noise
BS EN 8558 recommends that in a roof space, the loft insulation should be
Removed directly underneath the cistern to stop it freezing
The service pipe must be buried under the ground level to a minimum depth of
750mm
The service pipe terminates inside the building. At the end of the pipe there is a control device known as a
Service Stop Tap
The purpose of a service valve is to allow access to the float-operated valve for
Maintenance and Repair
One disadvantage of the direct system of cold water supply is that
If the main supply is shut off there is no cold water
In the direct system of cold water supply, all …………….. are connected directly to the rising main
Cold water draw off points
The ferrule is a means of
Isolating and disconnecting the services to a building
Water mains are the property of the
Water Authority
The service pipe buried beneath the ground to the recommended depth to prevent damage from
Frost penetrating down and freezing the pipe