cold water Flashcards

1
Q

Which British Standard makes recommendation on the minimum of cold water storage cistern for a particular property?

A

Bs6700

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
2
Q

The water flow rate from a cold water tap is 8 litres per minute, what is the flow rate measured in litres per second?

A

0.13 l/s

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
3
Q

The quantity of fittings delivered to site by a plumbers merchant will be shown in a

A

Delivery note

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
4
Q

Which type of cold water system is normally used in a dwelling which has a high incoming water pressure?

A

e)Direct.

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
5
Q

The Water Regulations require that the warning pipe in a small cold water storage cistern must be

A

Sized to be able to cope with the flow if water if the inlet valve fails

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
6
Q

What is the required soundness test pressure pipe which has a maximum operating pressure of 4 bar? for a copper cold water supply

A

6bar

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
7
Q

8 What is the minimum recommended clip spacing distance for a 15 mm vertical copper pipe?

A

1800mm

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
8
Q

Which one of the following components must be sited immediately after the supply stop valve on entry to a dwelling?

A

Drain valve

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
9
Q

Before leaving site, open ended pipework connected to a live but isolated cold water supply must be

A

sealed with watertight stop ends

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
10
Q

Which one of the following is a key feature of a direct cold water system?

A

Cold water outlets are taken from the rising supply pipe

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
11
Q

Which one of the following types of device is suitable to provide backflow protection for a pair of pillar taps to a kitchen sink?

A

AUK3 air gap.

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
12
Q

What is the minimum recommended distance between the top of a cold water storage cistern and an adjacent sloping roof?

A

350mm

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
13
Q

What should be carried out before undertaking a soundness test on a completed cold water system?

A

Visual inspection

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
14
Q

What is the minimum recommended distance for an insulated cold water service pipe entering a dwelling through a suspended timber floor? The distributing

A

No recommended

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
15
Q

The Water Regulations identifies that it is preferable to connect a cold water distributing pipe into a cistern at which one of the following locations? In the

A

base of the cistern

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
16
Q

What name is given to the spacer used when fixing a pillar tap to a stainless steel sink?

A

Top hat

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
17
Q

Which one of the following will most likely need to be informed before turning off the cold water supply to a rented house in order to carry out maintenance work?

A

Tenant

18
Q

When permanently disconnecting the cold water supply, Water Regulations (Byelaws) requires

A

create any dead legs in the pipework system

19
Q

What type of plumbing fitting is used to make a watertight seal to an open pipe end?

A

Stop-end.

20
Q

What type of plumbing fitting can be used to control the water pressure supplied to a shower?

A

Pressure reducing valve

21
Q

A maintenance programme in which float operated valves are re-washered annually regardless of whether the valve is defective is described as

A

planned preventative maintenane

22
Q

Which one of the following will cause the minimum of disruption when isolating the entire cold water supply to undertake a maintenance job lasting up to 4 hours in a food production factory?

A

Doing the job outside normal working hours

23
Q

Which one of the following is a replacement part for a pillar tap?

A

Rubber washer

24
Q

There is no water flow at the cold water outlets in a property. What is the most likely cause of a blockage

A

Fully blocked line strainer

25
Q

defective double check valve sited inside the property that is supplying an hose union bib tap can be repaired by

A

replacing the hose union tap with one that contains a double check valve

26
Q

replacing the hose union tap with one that contains a double check valve

A

replacing the hose union tap with one that contains a double check valve

27
Q

A plumber is most likely to be required to complete a maintenance record for a cold water system when working in which one of the following types of property?

A

Food production factory

28
Q

Food production factory

A

Food production factory

29
Q

The re-washering of a tap fails to prevent dripping at its outlet, which one of the following may overcome the problem?

A

Re-cutting the worn tap seat

30
Q

Which of the following is considered a reliable underground water source?

A

Artesian wells

31
Q

What makes water “plumbo-solvent”?

A

Soft water with added CO2

32
Q

What is the primary purpose of flocculation in water treatment?

A

To remove colour and turbidity

33
Q

Which system supplies water directly to all outlets without storage?

A

Direct cold water system

34
Q

What level of chlorine is typically added during disinfection?

A