Code Prep Flashcards

1
Q

The minimum height of water column allowed for testing underground drains is _______.

A

10’

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
2
Q

Shield plates used to protect pipes passing through the top or bottom plate of a wall must extend a minimum of ______ inches below the top plate or above the bottom plate.

A

2”

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
3
Q

When using air to test a part or all of a drainage system, air shall be pumped into the piping until there is a sufficient pressure to balance a ______ inch column of water column.

A

10’

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
4
Q

Piping under a slab must be a minimum of ______ inches deep.

A

No required depth

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
5
Q

A wood “oor joist cannot be notched on top or bottom more than _____ of its depth. Where can it NOT be notched?

A

1/6, middle 1/3 of the joist

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
6
Q

Opening made in walls or floors for the installation of pipe shall be seals by the use of ______ or ________

A

Caulk or casketing materials

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
7
Q

Horizontal Polypropylene Pipe that is 1-1/2 inch in diameter requires a hanger every _______ft.

A

4 ft

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
8
Q

When sleeves are installed to allow pipes to pass through walls or foundations, the annular space between the pipe and sleeve must be ______ in an approved

A

Sealed

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
9
Q

Air may be used to test a copper potable water system or any part thereof if ________.

A

If the pressure is not less than 50 PSI

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
10
Q

A test gauge used on a low- pressure test (10 PSI and below) must show pressure such that each mark on the dial represents

A

0.1

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
11
Q

A partition wall stud cannot be notched more than ______% of its depth. It cannot be bored more than ______% of its depth.

A

40% / 60%

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
12
Q

If you used air to test a drain line, the pressure gauge would have to read ______ PSI and the test would last _______ minutes.

A

5 PSI and 15 minutes

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
13
Q

A wood joist cannot be bored more than ________ of its depth and the hole shall be not closer than ______ to the edge.

A

d. 1/4, 1.5”

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
14
Q

The diameter of sleeves used to protect pipes passing through foundations, “oors or walls shall not be less than ______ than the pipe protected

A

2 pipe sizes larger

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
15
Q

If soft materials of poor load bearing qualities are found at the bottom of the trench, stabilization shall be achieved by over excavating a minimum ________ and backfilling to the installation level of the bottom of the pipe with #ne gravel, crushed stone or concert

A

a concrete foundation.

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
16
Q

If soft materials of poor load bearing qualities are found at the bottom of the trench, stabilization shall be achieved by over excavating a minimum ________ and backfilling to the installation level of the bottom of the pipe with #ne gravel, crushed stone or a concrete foundation.

A

2 pipe diameters

17
Q

Potable water service lines must be buried a minimum of _____ inches below the frost line and not less than ______ inches below grade.

A

6 in minimum and not less that 12 in below grade

18
Q

Bathtubs, showers, and lavatories are not required to be connected to the sanitary drainage system if they are connected to a _____________ system.

A

c. Grey water

19
Q

A vertical 6” cast-iron pipe that runs from the bottom “oor to the seventh “oor of a building. There is a distance of 14ft between the #rst and second and third “oors, of 12ft between all other “oors would require _______ pipe hangers or supports?
Outside drainage

A

5 pipe hanger

20
Q

Strainer plats installed on drain inlets shall not have an opening greater than _______.

A

1/2 inch

21
Q

Pipes passing through concrete or cinder block must be protected by protective sheathing or wrap with a minimum wall thickness of ______ inch

A

0.025