Circuits Flashcards
100% inductive load
100% reactive power, no real power
Current and voltage are out of phase by 90 degrees
The ratio of real power to apparent power will be equal to 0
Power factor of 0
100% reactive power
Inverse cosine of 0 = 90 degrees
Means the current and voltage are out of phase by 90 degrees
Power factor of 1
100% real power
Means the current and voltage are in phase
Power flow for a lagging power factor
Lagging power factor consumes reactive power
True of motors and inductive loads that require reactive power to generate a magnetic field
Power flow of a leading power factor
Leading power factor produces reactive power
True of capacitors
Power factor
Ratio of real power and apparent power
It is equal to the inverse cosine of the angle between the current and voltage
Z actual motor
(V motor) ^2 / S motor
V = voltage (V)
S = power (VA)
Symmetrical components notation
Positive = 1
Negative = 2
Zero = 0
Symmetrical components - phase equations
IA = IA1 + IA2 + IA0
IB = IB1 + IB2 + IB0
IC = IC1 + IC2 + IC0
Zero sequence components equations
IA0 = IB0 = IC0 = (IA + IB + IC) / 3
Positive sequence component equation
IA1 = (IA + aIB + a^2IC) / 3
Negative sequence components equation
IA2 = (IA + a^2IB + aIC) / 3