A disadvantage of magnetic particle inspection is that it is impossible to obtain any kind of permanent record of the indication.
false
How should a fluorescent dye be viewed?
under blacklight
The most likely cause of false indications is poor _______ (Hint: the answer is one word).
cleaning
Is there a standard for certifying operators for the eddy current method and for magnetic particle inspection?
yes
The potential drop method been used for which of the following research applications?
Measuring the growth of fatigue cracks.
Which of the following statements is true?
Eddy current is based on detecting changes in the inductive reactance of a coil due to disturbance of the eddy current by a disontinuity and can be used on non ferrous metals.
When using post-emulsifiable penetrants, the emulsifier must remain in contact with the surface long enough to mix with the excess penetrant but not long enough to reach penetrant in the discontinuities.
True
What is a potential effect of spraying on too much developer?
mask indications
The strength of the induced flux, and μ, is known as the
permeability
False indications are not associated with discontinuities, but non-relevant indications are.
True
What is the range of the applied field (relative to saturation) normally used in magnetic particle inspection?
30 to 70%
Which of the following best describes the basis of the magnetic particle inspection method?
Attraction of magnetic particles to a flux leakage field formed when a discontinuity lies perpendicular angle to the induce magnetic field.
To remove excess penetrant when using the solvent-removable process in a portable kit for spot checking:
Wipe away excess penetrant with clean cloth then wipe surface clean with cloth lightly wet with solvent cleaner.
To verify that any changes in procedure have not adversely affected the technique, a test is performed on a surface with known discontinuities. This surface is called a _________ (Hint: the answer is 2 words).
Comparator block
What type of developer is normally used with the solvent-removal process to spot check welds?
non aqueous
Does the liquid penetrant process work on stainless steel and aluminum?
yes
When using liquid penetrant inspection, the surface must be ground smooth to remove all irregularities before applying the penetrant.
false
The level of residual magnetic flux remaining in a ferromagnetic material when an applied field is removed is known as….
retentivity
Which of the following is a source of non-relevant indications that is NOT a result of material changes?
A and B - Excessive magnetizing field and residual magnetism.
A strike is avoided when using prods by turning the power on after the prods are in place, and turning the power off before removing the prods.
true
A welder is required to weld a plate that was previously magnetized for the detection of imperfections. What kind of problems can the welder expect to face when attempting to weld this plate?
arc blow
A typical current for prods spaced 150 mm (6 in) apart is ________amps.
600
These are the changes in a material that could cause a magnetic particle indication in the absence of a discontinuity.
Composition, microstructure, work hardening, and heat treatment.
Is there a standard for certifying operators using the liquid penetrant inspection method?
Yes CAN CGSB 48.9712