Chapter 9 Thermal Wells Flashcards

1
Q

BOP Elastomers should have a temperature rating of ____ degrees C and a peak working rating of ____ degrees C for one hour emergency services.

A

121C

177C

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
2
Q

Flexible hoses should have a temperature rating of ____ degrees C and a peak working rating of ____ degrees C for one hour emergency services

A

121C

160C

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
3
Q

Drilling fluids usually consist of brine solution. Increase in temperature will ____ the effective brine weight.

A

Decrease

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
4
Q

Why are ECD’s a consideration in thermal wells?

A

ECD’s increase with measure depth, losses might occur into the pair well as the fracture gradient of the horizontal formation doesn’t change.

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
5
Q

The recommend reserve drilling fluid additives and volume while drilling thermal wells are ___%.

A

50%

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
6
Q

True or False: any well drilled into, or in close proximity to a thermally enhanced reservoir can be considered to be a Thermal well.

A

True

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
7
Q

True or False: While drilling a thermal well, risks are associated with drilling the vertical section as the caprock integrity might be compromised.

A

True

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
8
Q

Key steps in producing the drilling program for a thermal well are :

A
  • Determine the outer boundaries of the production affected area.
  • Communicate with nearby status of wells proximal to your operations.
  • Consider the heating of wellbore fluids during trips or extended periods of downtime.
  • Drilling fluid contamination.
  • Create the deviation control program (this is issued for all wells including intended straight holes).
  • Estimate the uncertainty in the evaluation of the pore pressure.
  • Consider the lack flexibility in casing seat selection due to directional constraints and caprock.
How well did you know this?
1
Not at all
2
3
4
5
Perfectly
9
Q

When drilling both the caprock & thermal sections of a well the following should be considered:

A
  • Closely monitor returns and drilling fluid temperature while drilling.
  • Check all drill pipe to ensure hard banding is of “flush” to minimize potential casing wear.
  • Drilling operations should be suspended if the temperature of the drilling fluid return at surface could present a hazard to personal.
  • When not circulating, the well should be monitored continuously and consider circulating continuously across the trip tank.
  • The trip tank should be kept half full when in use. If it is not being used, the contents should be pumped out and replaced every tour.
How well did you know this?
1
Not at all
2
3
4
5
Perfectly