Chapter 5 Building Construction Flashcards
Cold drawn steel such as cables, rebar, and light weight fasteners lose 55% of its strength at _________
800°F
Extruded structural steel used for beams and columns loses 50% of its strength at _________
1100°F
At 1100°F, a 100 foot long been can elongate_________
10 inches
The triangular truss is the most common truss used to form a _________ roof
Peaked
_________ connections use nuts and bolts, screws, nails, rivets and similar devices to transfer a load through attached elements
Pinned
Beams resting on exterior walls are simply called _________ buildings
Wall bearing
A _________ is a non-loadbearing wall that supports only itself and is used only to keep whether out
curtain wall
A prescriptive code tells the user house something has to be accomplished, we’re as a _________ tells the user what something needs to do when it’s done
Performance-based code
Structural failure is often the result of a _________ failure
Connection