Chapter 4 quiz Flashcards
Which reference electrode is best suited for soil?
CSE
The positive lead of the voltmeter should be placed on the structure during a structure-to-electrolyte potential reading. (true or False)
true
Standard hydrogen electrodes are commonly used in the field.
false
The three criteria recommended by NACE are:
-850mvCSE with Cp applied, -850off,
100mV polarization
The native potential can be calculated by subtracting
The polarization from the polarized potential
IR drop is calculated by subtracting
The polarized potential from the applied potential
IR drop must be considered for the -850 mV polarized criteria.
false
IR drop must be considered for the -850 mV applied criteria.
true
IR drop must be considered for the 100 mV polarization criteria.
false
-850 mV applied is the most widely used criteria.
true