Chapter 4 Flashcards
What type of power flaw involves a fluctuation in voltage levels caused by other devices on the network or by EMI? A) brownout B) blackout C) noise D) surge
C) noise
One watt is equal to how many volt-amps? A) 1.4 B) 2 C) 10 D) 1,000
A) 1.4
What is the maximum allowable distance for horizontal wiring? A) 100 ft B) 100 m C) 90 m D) 90 ft
B) 100 m
The radius of the maximum arc into which you can loop a cable without impairing data transmission is known as what option below? A) metal stress factor B) arc coefficient C) bend radius D) flex rating
C) bend radius
How far away from fluorescent lights or other sources of EMI should cable be installed? A) at least 3 ft B) at least 5 ft C) at least 10 ft D) at least 20 ft
A) at least 3 ft
What is the industry standard for rack height in rack units? A) 18U B) 22U C) 42U D) 54U
C) 42U
Which method of transmission allows signals to travel in both directions over a medium simultaneously? A) half duplex B) simplex C) full-duplex D) multiplex
C) full-duplex
Which method of transmission allows signals to travel in both directions over a medium but in only one direction at a time? A) full duplex B) half duplex C) simplex D) multiplex
B) half duplex
Ethernet exists at what layer of the OSI model? A) Layer 1 B) Layer 2 C) Layer 3 D) Layer 4
B) Layer 2
What is the maximum frame size for Ethernet ll frames on a VLAN? A) 1500 bytes B) 1518 bytes C) 1522 bytes D) 1496 bytes
C) 1522 bytes
When selecting a punch down block, what block type is more suitable for data connections? A) 10 block B) 22 block C) 66 block D) 110 block
D) 110 block
What component of the backbone runs between a building's floors and can be used to connect an MDF and IDF or multiple IDFs? A) horizontal cross connect B) patch cable C) vertical cross connect D) diagonal cabling
C) vertical cross connect
Where is a demarc located in relation to the structured cabling of an enterprise environment?
A) in the Main Distribution Frame (MDF)
B) at the Intermediate Distribution Frame (IDF)
C) in the work area
D) between the MDF and the IDF
A) in the Main Distribution Frame (MDF)
Select the component of enterprise level structured cabling that serves as the location where an incoming network interface enters a building and connects with the building's backbone cabling: A) network interface device B) main distribution frame C) intermediate distribution frame D) entrance facility
D) entrance facility
During termination of twisted pair cabling, what should be done to ensure minimal cross talk is introduced?
A) No more than 1 inch of the cable should be exposed
B) No less than 1 inch of the cable should be exposed
C) Each pair should be stripped of insulation so that it doesn’t get caught in the jack
D) Each pair should be twisted around another pair to reduce cross talk
A) No more than 1 inch of the cable should be exposed