Chapter 2 Flashcards
The U.S. department of transportation regulations require that a hydrostatic test is performed on composite cylinders every _____ years by a certified testing facility.
5 years
The life span of a composite cylinder is ____ from date of manufacture.
15 years
The weight of a carbon fiber- wrapped cylinder is _____.
14 lbs.
A 45 minute rated composite cylinder contains _____ cubic feet of air pressurized to 5500 psi.
66 cubic feet
Scott AP 75 5.5 air-pak assembly weight?
30 lbs.
The 45 minute rating time calculation is based on a baseline breathing rate of ______ established by NIOSH.
40 LPM (liters per minute)
The rubber/plastic bumper at the base of the cylinder valve assembly contains what?
A radio frequency identification (RFID) chip
What does the RFID chip at the base of the cylinder log?
Information pertaining to the cylinder such as, fill date, fill time, fill location, member ID who filled, manufacture date and last hydrostatic date.
P.a.s.s (PASS) stands for what?
Personal
Alert
Safety
System
Dual EBSS (buddy breathing) hose is how long?
3 feet or 36’’ of hose
The Scott face piece is what model?
3M Scott vision C5 facepiece
The pressure reducer assembly is located where on the back frame?
Left side of the back frame
What does the pressure reducer assembly contain?
- Redundant dual path reducing systems
- Primary and secondary reducing circuits
- automatic transfer valve
- over pressure valve
The primary reducing circuit reduces the air pressure to ____________.
100 PSI
The secondary pressure reducing circuit reduces the pressure of the air flowing from the cylinder to the mask mounted breathing regulator from cylinder pressure to _____
150 PSI
The spray bar is comprised of ____ holes in the upper part of the regulator assembly.
9 holes
What is the purpose of the spray bar?
Keeps the face piece clear of condensation.
The breathing regulator produces a pressure of approximately ______ above atmospheric pressure inside the face piece.
.036- .054 psi
The SCBA safety relief device on the cylinder
Frangible copper disc
Photo luminescent identifier is attached to the _______ shoulder strap
Right
Photo luminescent identifier unit ID in color for the
Officer
Photo luminescent identifier colored background for
Firefighters
Storage pouch for the EBSS is on the
Left side
To connect the low pressure hose with the quick disconnect, the user must align the ________
Heads up display electrical connection
RIC/UAC is on the base of the harness on the ________ side
Left
The extra ___ psi supplied by the secondary pressure reducing circuit activates the vibralert alarm, an audible end of service time indicator.
50
Vibralert alarm is an audible and tactile End of Service Time Indicator (EOSTI) that warns the user that less than ____ of the full pressure _________ remains in the air supply cylinder.
33 % (1800 psi)
When air pressure remaining in the cylinder falls to ______ of the full pressure _______ or the primary reducing circuit fails in the closed position, a transfer valve opens allowing the secondary pressure reducing circuit to function.
33 % (1800 psi)
In the event the primary reducing circuit fails in the open position and the secondary reducing circuit opens, air at over ______psi to enter the outlet manifold , the relief valve on the outlet manifold will open.
225 psi
The outlet manifold of the pressure reducer assembly contains a resettable over pressure relief valve set at
225 psi
The auto air saver switch is located on the _______ side of the mask mounted breathing regulator.
Right
The purge valve is located on the _______ side of the mask mounted breathing regulator.
Left side
During normal operation, the purge valve shall be in the off position, with the indicator on the knob pointing to the ___________
Twelve o’clock position
A constant flow of at least _______, can be obtained by rotating the knob one half turn counterclockwise
4.4 cubic feet (125 liters per minute)
If the vibralert alarm activates when the SCBA is in use, the wearer must
Immediately notify their officer and or partner and must immediately leave the contaminated atmosphere.
Vibralert alarm could mean what of three things
Air is 33% (1800 psi)
Primary reducing circuit failed closed, secondary circuit is now in operation
Primary reducing circuit has failed open, air more than 225 psi has entered the outlet manifold. (You will hear loud air escaping)
Heads up display consist of how many lights
Four rectangular for cylinder pressure and a fifth battery shaped to the right for low battery
When turned on, the heads up display will illuminate all five lights for _______
20 seconds
HUD 2 green lights
Full cylinder
HUD 1 green light
Three quarters cylinder
HUD 1 yellow light flashing slow at once a second
One half cylinder
HUD 1 red light flashing 10 times a second
1/3 cylinder
HUD the red light flashes how many times a second ______
10 times a second
HUD the yellow light flashes _______ times a second
Once a second
To avoid radio frequency interference, antennas of radios should be held ___ away from the control console with remote pressure gauge and the sensor module of the pak alert distress alarm.
6 inches
The data logging feature records the date and time of the most recent ________ events.
Thousand events
In monitoring mode, the Scott pak alert constantly monitors motion of the SCBA back frame. If the motion sensor does not sense motion of the SCBA for _____ , the pak alert will signal a pre alarm condition.
20 seconds
If there is still no motion of the SCBA after the pre alarm, the full alarm will sound in _____ .
10 seconds
Once activated in monitoring mode, the Scott pak alert will remain activated until
Cylinder is turned off (residual air purged) and reset button on the control module has been pressed twice.
With fresh alkaline batteries, the pak alert will stay in monitoring mode (green flashing light with no sound) for about ______
1000 hours
With fresh alkaline batteries, the pak alert will last in full alarm (red flashing light) for about __ hours.
8 hours.
To reset the alarm on the control console, push the reset button ____
Twice
The three sizes of the 3M Scott Vision C5 facepiece?
Small medium and large
To transmit on a portable radio when wearing a facepiece, place the microphone ____ away from and in line with the speaking diaphragm.
1/2”
Damaged facepiece must be
Tagged with SCBA repair request form and taken to the mask room for repair or replacement.
If a defective facepiece cannot be immediately repaired, loaner facepieces are available through________?
The on duty safety battalion chief.
Pak tracker can detect a signal up to _________
900 feet (straight line of sight)
Pak tracker locator has been programmed to transmit a code that enables search teams to identify up to _____ locator transmitters simultaneously in alarm mode.
36
Pak tracker frequency
2.44 GHz RF signal
Pak tracker large start up buttons
Left (scroll)
Right (enter)
Sensor module has what type of batteries and how many?
6 AA batteries
Sensor module lights Start up (open cylinder)
Bright light then flash green
Sensor module lights Normal operation
Flash green
Sensor module lights Cylinder low air 1/3
Flash orange (alternating)
Sensor module lights Low battery while on
Flash orange once a second
Sensor module lights Shut down
Lights off
Sensor module lights Press reset w/ unit off (battery test)
Bright light then
Flash green if good/ flash red if bad
Sensor module lights Press manual alarm with unit off
Flash green then full alarm flash red
Sensor module lights Press reset from manual alarm
Returns to flash green
Sensor module lights Pass pre alarm
Flash red (alternating)
Sensor module lights Pass full alarm
Flash red (simultaneously)
If any malfunction of the Pak tracker locator is noted during inspection
Remove from service
Tag
Return to the mask room
Turn on the pak tracker handheld receiver by
Pressing both select and scroll buttons simultaneously
Handheld receiver (pak tracker) In non tracking mode, the batteries will last ___ hours.
12 hours
Handheld receiver (pak tracker) in tracking mode the batteries will last ___ hours.
6 hours
When the battery in the handheld receiver has approximately _____ of its life remaining. The “low batt” light will glow yellow.
20%
The handheld receiver will operate for approximately ___ in the low battery condition.
45 minutes
The handheld receiver battery can be recharged up to ______ times.
500
Pak tracker receiver, The high intensity bars illuminate when the strength is greater than ______
50%
Pak tracker hand held receiver, to clear the identification number on the handheld receiver by holding the scroll button down for ________-
3 seconds
Transmitter designations (truck)
DC T10 O officer T-10-1 L hook 2 R bar. 3 D driver. 4 T tiller 5
Hook L for leftside
Bar R for rightside
Transmitter designations (rescue squad)
DC RS3 O. 1 TA. 2 TB1. 3 TB2. 4 D. 5
Transmitter designations (engine)
Dc E15 O. Officer 1
R. Line. 2
L. Layout. 3
D. Driver 4