Chapter 1 (Railroad facilities and track roadway) Flashcards

1
Q

Transmission lines are how many volts

A

132,000 volts

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
2
Q

Catenary “trolley” wires are how many volts?

A

12,000 volts

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
3
Q

Signal power lines are how many volts?

A

6,900 volts

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
4
Q

Order of lines in the catenary system

A

Ground (static)

Transmission 138,000

Signal power 6,900

Catenary “trolley” 12,000

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
5
Q

In an emergency, the catenary system must be shut down by Amtrak personnel in ?

A

Philadelphia

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
6
Q

In an emergency, the catenary system must be grounded by who?

A

Onsite Amtrak class A lineman or electrician

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
7
Q

In the absence of class A electrians, the catenary system can be shut down and grounded by who?

A

Foreman and class B employees in the two sections of the ivy city yard

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
8
Q

On downed catenary lines, stay _____ ft away

A

15

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
9
Q

Transmission lines stay how far away

A

Nothing allowed within 8 ft

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
10
Q

Signal power lines, objects must not be allowed within ____ feet

A

3

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
11
Q

Catenary lines “trolley” objects must not be within _____ ft

A

3

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
12
Q

Impedance bonds

A

Electrical devices that permit passage of higher voltage propulsion current but prevent the passage of lower voltage signal current.

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
13
Q

Wires connected to the impedance bonds are called what?

A

Leads

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
14
Q

Where are impedance bonds located

A

Near rail signals between rails

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
15
Q

Impedance bonds are a electrocution hazard (true/false)

A

True

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
16
Q

How long does it take class A employees to arrive on the scene

A

1 hour

17
Q

What is used to ground power lines

A

Grounding stick with the grounding wire from the stick to the rail

18
Q

Overhead catenary lines can arc up to ___ ft

A

3 ft

19
Q

Some switches are operated as far away as

A

Jacksonville fl

20
Q

Some switches may have up to _____

_________gallon LPG tanks to supply the heater

A

6

1000

21
Q

Markers are spaced how far apart?

A

1 mile

“Milepost”

22
Q

Static wires contain how many volts

A

0

23
Q

Transmission lines how many volts

A

138,000

8ft away (arc)

24
Q

Signal lines how many volts?

A

6,900

Stay away 3 ft (arc)

25
Q

Trolley wires how many volts?

A

12,000

Stay away 3 ft (arc)

26
Q

Passing trains: safe distance

A

30 feet

27
Q

Standing train: safe distance

A

25 feet

28
Q

Apparatus from centerline

A

15 feet