Chapter 1 - 5 Flashcards
A building permit is required for a fence how many feet in height?
Over 7ft
Size of Address Numbers
4 in height x 1/2 in width
Clear height above and below a mezzanine floor shall…
Be no less than 7 ft
a mezzanine shall be open and unobstructed to the room ….
42 inches
To qualify for area factor increase…
shall have no less than 25% on public way perimeter.
To qualify for area factor increase based on Frontage…
shall have a minimum of 20 ft
Sprinklered and Non-sprinklered building public ways no less than…
60 feet. (section 507)
Sloped glazing is glass or translucent material installed at a slope of ….
15 of more from vertical
Retaining wall won’t need a permit if…
under 4 ft.
A permit is not required for one-store detached accessory structure if max floor is…
120 square feet.
aggregate accessory occupancies shall not occupy more than…
10% of the building area of the story
high-rise structure is every building of any type of construction/occupancy use for humans located more than…
75 feet above the lowest level having building access.
Each portion of a building separated by one or more…
Fire Wall
What occupancy shall be separated from other occupancies?
Group L
Separated occupancies in 1-story building shall be separated by…
Fire Barriers
A mall (open or closed) shall be surrounded on all sides by a permanent open space no less than..
60ft
Max floors for Mall are
3 floors
Interior finish in mall shall have minimum ….
Class B for minimum flame spread index and smoke-developed index
Plastics used in signs shall have a self ignition temperature of
650 *F
Aggregate clear egress width of the mall…
shall be no less than 20 ft
equipment platforms within a room shall not be greater than
2/3 of the area of room
Do you need separation between main and accessory occupancies?
No
Required separation of occupancies shall be
Fire Barrier