Fire hydrant and fire flow requirements are based upon?
Land use
*Fire apparatus access roads: approved FA access roads shall comply with the requirements of this section and shall extend to within _____’ of all portions of the facility and all portions of the exterior walls of the ______ story building.
150’, 1st story
if the building structure is MORE THAN 150’ from the edge of the roadway of an approved street, an approved _____ _____ shall be provided so that such portion is within 150’ of….
Fire Lane
Dead end access: when required access is provided by an improved street, fire lane or combination of both which results in a dead end excess of _____ feet, at least one additional ingress-egress roadway shall be provided
700 feet
Fire lanes shall be designated and maintained as follows: fire lanes shall have a minimum clear roadway of _____ feet when no parking is allowed on either side.
20 feet
Those portions of a fire lane which must accommodate the portion of FD aerial ladder, shall have a clear roadway width of _____ feet when no parking is allowed on either side
28 feet
those portions of fire lane _____ feet on either side of a PRIVATE fire hydrant shall have a minimum clear roadway width of _____ feet. NO PARKING permitted within those portions of the roadway which are within _____ feet of and on the same side as a PRIVATE fire hydrant
30, 28’ 30
where parking is allowed on ONLY ONE SIDE of a required fire lane, parking shall be on the same of the road as the fire _____
hydrants
where PARALLEL parking is allowed on either side of a FIRE LANE, the roadway width shall be increased by _____ feet for each parking lane
8’
where access requires accommodations of fire department apparatus, overhead clearance shall not be less than _____ feet
14’
Dead end fire lanes shall TERMINATE in culdesacs or other approved turning areas consistent with Dept. of _____ _____
public works
Fire Department access roads shall have an unobstructed WIDTH of no less then ___ feet exclusive of shoulders, except for approved security gates, and unobstructed VERTICAL clearance of no less than ____ feet and ___ inches
20’, 13’6”
Dead ends: dead end fire access roads greater than ____ feet shall be provided with an approved area for turning around fire app.
150’
OBSTRUCTIONS on FIRE roads and firebreaks: no person shall install or maintain an antenna wire no less than _____ feet above a fire road or firebreak
16’
Fences and gates: school grounds may be fenced and gates therin may be equipped with locks provided that SAFE DISPERSAL AREAS are based on _____ square feet per occupant are located between the school and the fence
3