Ch 4 Ladder Company Ops Flashcards
When entering a room to search, the door to the room shall be closed, after a quick check/sweep of the floor in the hall outside for any victims. The door shall then be kept closed until when?
The main body of fire has been extinguished.
2.1, 2.2
When is the primary function of the engine company to protect the interior stairs in a PD fire?
If MORE THAN 1 occupant is found on an UPPER floor.
note: IC shall ensure adequate staffing to effect their removal during this critical period.
2. 4
What is a quick way to check for the presence of a sole plate to determine if the building is balloon frame?
Remove a baseboard on an exterior wall. If none is found, treat as balloon construction.
(3.1)
It is common in balloon frame construction for fire to pass vertically via exterior wall channels created by the continuous studding. Fire will spread to the attic space and bypass intermediate floors.
True or False
True. 3.2)
Which Ladder company is generally responsible for roof ventilation in a flat roof PD?
Peaked Roof?
Flat roof- 1st due
Peaked roof-2nd Due
(4.1, 4.2)
What is the primary consideration for access to a cellar fire in a PD?
The entrance door providing QUICKEST access to the fire area.
(5.1)
T or F
The Ladder company officer conducting a search on the fire floor of a PD should be the only one to initiate the request for additional ventilation on that floor?
True. He controls the entire floor. (5.1 A.12)
Members proceeding to the rear in peaked roof operations must do a visual inspection of what?
Cellar windows, to determine interior fire conditions.
5.1
The OV of L-109 was made his way to the rear of a peaked roof PD because no aerial or portable ops were needed in front. Upon arrival back there he noticed window bars on the first floor windows and a rear entrance. He then notified his Officer. Was this action correct?
No. Immediately Notify IC of means of entry other conditions found. IC must special call an Engine, Truck so he is the logical person to notify.
(5.1. 5)
Which truck company initiates removal of window bars on both the front and rear of the building? Peaked-roof.
a) 1st Due Truck
b) Second Due
c) Special Called truck
1st Due Truck. Early in the operation if conditions allow. (search & rescue duties may preclude window bar removal) (5.1 5)
The Roof/Ov team up to VEIS from the exterior. After conducting a quick perimeter survey and finding no visible life hazard, they performed VEIS of an upper floor that was most likely to be occupied. They brought a portable ladder and a 6’ halligan hook and/or halligan for each member. Did they operate correctly?
Yes. (5.2)
In situations where size-up indicates an obvious occupied attic, who will utilize the aerial or TL to perform VEIS of the attic area?
1st LCC when teamed up with 2nd LCC or other available member.
(5.3 B5)
T or F
The 1st arriving LCC shall position the aerial to cover the front of the building. Perimeter searches will be handled by roof/ ov.
False.
Position aerial to cover 2 sides of the building.
(5.3 B)
L-111’s LCC heard reports that the fire had been knocked down on the first floor. No members inside the building were in immediate danger that would require the use of the aerial ladder, so he entered the dwelling to assist his company with searches. Was this the correct move?
No. Fire must be controlled AND no members in immediate danger. (same goes for TL LCC)
(5.3 B6)
A properly positioned TL can reach_______-
The front and side windows on the upper levels. (5.4 B note)