NFPA 54 is what code?
National fuel gas code
What is the purpose of a barometric damper
Allows air directly into venting system; and reduces draft through appliance
What does rise & run mean?
Length of connector should not exceed 75% of venting system height above connector
What is the fireplace minimum clearance for side walls and rear walls?
2”; 4”
Combustibles such as trim or mantels shall NOT be placed within ____” of fireplace opening(NFPA211)
6”
Combustibles above and projecting more than 1 1/2” from opening, shall NOT be within ____” of fireplace opening (NFPA211)
12”
If fireplace opening is less than 6 sq. ft. the hearth must extend to ___” to each side and ___” in front of the fireplace opening. (864 sqr. inches)
8”; 16”
How do you find the square feet of a square?
Length x Width
How do you find the square feet of a circle?
Radius x Radius x 3.14
What is the purpose of a catalytic?
Created to increase the combustion efficiency of. a wood heating system by lowering ignition temps of flue gases pushing through it
A B-vent must be vented vertically and uses ____ to provide oxygen to a fire.
Fresh air from inside the home
A direct vent has a sealed glass front and pulls all its _____. Direct vents can be vented vertically or horizontally through exterior wall. Direct vents are completely sealed.
air from outside the home
36” of clearance is required from stove to an unprotected wall for a freestanding stove. True or False
True
How much clearance do you need from the venting system to the wall behind a wood burning stove?
18”
(Floor Protection) How much clearance from the wood stove to the side of the hearth and the front of the hearth do you need?
18”
What is uL103/uL103HT?
Standard by underwriters laboratories for factory built chimneys for residential type heating appliances (1700* test ul103/2100* test ul103HT)
UL127
standard by Underwriters lab for factory built fireplaces including fire chamber chimney, roof assembly, etc.
UL641
Standard by underwriters lab for low temp venting systems (Oil, gas, pellet)
ASTM
American Society for testing and materials, producing standards for fireclay, building brick, refractory mortars, clay flue lining
ASHRE
American society for heating
AHJ
The authority having jurisdiction- sets requirements based on its concept of having a safe instell
AHJ
The authority having jurisdiction- sets requirements based on its concept of having a safe instell
Standard of care
Legal term; Do your best, don’t leave things out when talking to clients
Combustion (3 words)
Heat, Fuel, Oxygen