Cathodic Protection Flashcards
Limitations of CP
Internal surfaces not protected Above ground surfaces not protected Electrical Shielding Stray Current Attenuation (gradual loss of current)
Produce small amounts of current Cannot be adjusted No power source needed
Galvanic System
Galvanic System Anodes
Aluminum, Zinc and Magnesium
Produce any amount of current Can be adjusted Power source is needed
Impressed Current System
Impressed Current Anodes
Graphite, High Silicone Cast Iron, Scrap Steel, Mixed Metal Oxide (MMO), Titanium-Niobium, Platinum, Lead-Silver
Impressed Current Power Sources
Rectifiers Photovoltaic Solar Panels Thermo-Electric Gen Engine Generators Fuel Cells Wind Mill Power
Closed Cycle Vapor Turbo Gen Batteries
Anode Backfill
Lowers contact with resistance to Earth; Enables anodes to consume uniformly; Lengthens the life of Impressed Anodes; Holds moisture for galvanic anodes; Must be designed to fit the ground-bed
Reference Electrodes
Copper Copper/Sulfate Hydrogen Zinc Calomel Silver Silver/Chloride Antimony
The positive terminal of an ICCP must be attached to the …..?
Ground bed
Most common reference cell used for CP?
Copper/Copper-Sulfate
What measurements are used most commonly as a criterion of protection for CP?
Potential
Coated pipe lines polarize very ……; the better the coating the ……. the polarization?
Rapidly; Faster
The lower the resistivity; the …… will be the corrosivity?
Higher
The Wenner 4 pin test is used to measure ……. which is then utilized to calculate ………
Voltage (potentials), resistivites
In tankers tanks that are filled with salt water for ballast after discharging cargo are suseptible to severe corrosion; …….. anodes are widely used to prevent corrosion?
Galvanic
Metal that provides sacrificial protection to another metal that is more noble when electrically coupled in an electrolyte?
Galvanic Anode
Ratio of an anode weight sacrificed for CP divided by total theoretical amperes hours or capacity of the material used.
Galvanic Anode Efficiency
Ground bed anodes are not depended upon as a source of electrical energy. An external source of DC power is connected between ground bed anodes and structure.
Impressed Current CP (ICCP)
Device that is powered by electrical utility system which converts high voltage AC to low voltage DC by means of step-down transformers.
Rectifier
Change from open-circuit potential as a result of current across the electrode/electrolyte interface
Polarization
3 Sources of DC stray current
DC Railway systems; Mining operations using DC power; DC welding Operations
Closed interval potential survey is to record the potential profit of a pipeline over its entire length by taking potential readings at intervals of approximately M
CIPS
Pearson Survey and DCVG survey have in common?
They are tests designed to locate coating defects in buried pipelines.
Pearson Survey and DCVG survey are different?
Pearson Survey - no trailing wires and the defect gives a signal. No signal in DCVG means a defect.