Cards Flashcards
What is the max gross weight of the B206 L4
4450 lbs
Is there a slope limitation on the L4?
No
What is the VNE with doors off?
90kts
What is the starting TOT limits?
100-716 Continuous
716-768 5 min take off (Do not exceed 10 seconds above 768)
871 Max Transient
927 for starting and shutdown 1 second
What are the starter limits when starting?
—-Battery—-
60 sec/60 sec
60 sec/60 sec
60 sec/ 30 min off
—Pack—-
40 sec/30 sec
40 sec/30 sec
40 sec/30 min
VNE for arm/disarm floats
60kts
What are the torque limitations?
0-75 continous
75 - 100 5 min take off
100-105 transient (max 5 sec)
What is the VNE with 85-100% torque applied?
84 kts
What are the transmission oil temperature limitations?
15-110c
110 max
What are the rotor limitation’s power on?
99-101% continuous
104% max 5 min low power decent
Rotor RPM power off?
Minimum 90%
Maximum 97%
Max baggage compartment weight?
250lbs
86in per sq ft
What Nr should we avoid during ground ops?
71.8-91.5 N2
What is the aircraft’s VNE?
130 kts
VNE autorotation
100kts
If using the APU the max amp allowed?
500 amps
Define land as soon as practical
Landing site and duration of flight are at the discretion of the pilot. Extended flight beyond nearest approved landing area is not recommended.
Define Land as soon as possible
Land without delay at nearest suitable area at which a safe approach is reasonably assured.
ENG OUT
Fault - Gas producer less than 55 +- 3% rpm. Power turbine rpm decreasing
Verify engine condition. Accomplish engine failure procedure
Battery Hot
Fault - battery overheating temperature 140 F (60c) or higher
Turn BAT switch OFF and land as soon as practical. If battery RLY caution light illuminates, land as soon as possible.
Litter Door Open
Fault- litter door not securely latched
Close door securely before flight. If light illuminates during flight, land as soon as practical.
ROTOR LOW RPM
Fault - Rotor below 90%
Reduce collective and ensure throttle is full open. Light and audio should cease when rotor increases above approximately 90% RPM
TRANS OIL PRESS
Fault - XMSN OIL pressure is below minimum
Reduce power; verify fault with gauge. Land as soon as possible.
TRANS OIL TEMP
Fault- XMSN OIL temperature is at or above red line.
Reduce power; verify fault with gauge. Land as soon as possible
Battery RLY
Fault - Battery relay has malfunction to closed position with BAT switch OFF. Battery will not drop off line.
If Battery Hot light is illuminated land as soon as possible.
FUEL LOW
Fault - Approximately 10 gallons of gas fuel remaining
Verify FUEL QTY. Land as soon as practical.
Newark Frequency
127.85
118.3
Company Frequency
131.575
Kearny Frequency
131.975
The River (Hudson)
123.05
Guard freqency
122.5
Transmission Oil Temperature
0-107 degrees C
LaGuardia Frequency
126.05