C3 Code 2010 Flashcards
Code 2010
On a wall over 10 foot what type purlin should be used?
1) continuous top chord
2) top chord
3) none required
4) safety permanent brace
Continuous top chord
Nailing boundary is what?
1) illegal nailing pattern
2) finish pattern
3) nailing pattern required by design at boundaries of diagrams
4) framing pattern
3) nailing pattern required by Design at boundaries of diagrams
Water-based barriers applied over wood based sheathing, should include a barrier performance at least the equivalent to 2 layers of _____?
1) grade A paper
2) grade B paper
3) grade C paper
4) grade D paper
Grade D Paper
Notching exterior walls and partitions is permitted to depths not exceeding ______ of it’s width, Non - bearing not exceeding ______ of it’s width.
1) 20% / 40%
2) 25% / 40%
3) 40% / 20%
4) 40% / 25%
25% / 40%
The min. net clear opening height for emergency escape should be ____ and min. net clear width should be____?
1) 20/24
2) 36/24
3) 24/36
4) 24/20
24/20
Emergency escape and rescue openings should have the bottom of the clear opening not greater than ____ inches measures from the floor.
1) 50
2) 52
3) 38
4) 44
44 inches
Bearing and exterior wall studs shall be capped with double top plates to provide over lapping at the corners. End joints in double top plates shall be offset at least ____ and nailed with not less than ____ nails on each end.
1) 42?15D
2) 48/16D
3) 48?15D
4) 38/16D
48” / 16D Nails
Minimum thickness of wood board of wall sheathing spacing 24 inches on center?
1) 5/8 inch
2) 1/2 inch
3) 1 inch
4) 3/4 inch
5/8 inch thickness
Attic spaces shall have a clear height of over ___ inches min. clear headroom.
1) 30 inches
2) 50 inches
3) 24 inches
4) 42 inches
30 inches of headroom
End joints in double top plates shall be offset at least ____inches and shall be nailed with not less than____ 16D face nails on each side of joint
1) 24/4
2) 32/6
3) 48/8
4) 40/12
48 inches/ 8d nails
What is the min. width required for a sidewalk around a construction site?
1) 3’6”
2) 4”0”
3) 4’6”
4) 2’6”
4’0” min. sidewalk width
The bottom surface of a footing is permitted to have slope. But not to exceed a slope of ____?
1) 10%
2) 5%
3) 0%
4) not required
10% slope
Clay tile shingle perimeter fastening areas include 3 tile courses but not less than ____from either side of hips or ridges and edges of eaves and gable rakes.
1) 36 inches
2) 24 inches
3) 42 inches
4) 20 inches
36 inches
An ice barrier for roofing shall consist of at least ____ of underlayment. Cemented together or of a self adhering polymer bitmen sheet, and extend from the lowest edge of roof surfaces to a point at least ____ inside the ext. wall line of the building.
1) 1 Layer / 12 inches
2) 2 layers / 24 inches
3) 3 layers / 36 inches
4) 1 layer / 42 inches
2 layers / 24 inches
Purlins shall be continuous and shall be supported by ____ braces installed to bearing walls at a slope not less than ____ degress from the horizontal.
1) 4” x 10” / 20 degrees
2) 3” x 6” / 30 degrees
3) 1” x 2” / 10 degrees
4) 2” x 4” / 45 degrees
2” x 4” / 45 degrees