C182 G1000 Flashcards
1
Q
Emergency Checklist: Bold Item
Engine Fire in Flight
A
- Mixture control-idle cutoff
- Fuel selector-rotate down to off
- Fuel Pump-off
- Standy battery switch-off
- master switch (alt/bat)-off
- Cabin heat/air-off
- airspeed-100 KIAS. (If fire is not extinguished, increase glide speed to find an airspeed within which airspeed limitations, which will provide an incombustible mixture)
- Forced landing-execute
2
Q
Electrical Fire in Flight
A
- Standby battery switch-off
- Master switch (alt/bat)-off
- Vents/cabin air/heat-off
- Fire extinguisher-activate
- Avionics switch (bus 1/2)-off
- All other switches (except magnetos)-off
- WARNING: after fire extinguisher has been used, be sure that the fire is extinguished before exterior isused to remove smoke from the cabin
- Vents/cabin/air-open
- if fire has been extinguished, go to nearest suitable airport or landing area
- Master switch (Alt/Bat) -On
- Avionics Bus 1/2-On
3
Q
Cabin Fire
A
- Standby Battery Switch-Off
- ** Master switch (alt/bat)-offli>**
- Vents/Cabin/Air-closed
- Fire extinguisher-Activate
- Vents/cabin/air-open
- Land as soon as possible to inspect for damage
<!--
-->
4
Q
Engine Failure During Takeoff Roll
A
- Throttle-idle
- Brakes-apply
- Wing flaps-retract
- Mixture-idle cutoff
- Magnetos-off
- Standby Battery switch-off
- Master switch (Alt/Bat)-off
5
Q
Fire during ground start
A
- ** Magneto switch-continue cranking**
if engine starts
- power 1700 RPM for a few minutes
- engine-shut down and inspect engine
if engine fails to start
- throttle control-full open
- mixture controle-idle cutoff
- magentos-continue to crank
- fuel pump-off
- magentos-off
- standby battery switch-off
- master (Alt/Bat)-off
- engine-secure
6
Q
Vx
A
65 KIAS
7
Q
Vy
A
80 KIAS
8
Q
Vso
A
41 KIAS
9
Q
Vs
A
51 KIAS
10
Q
Vg
A
76 KIAS
11
Q
Va at 3100#
A
76 KIAS
12
Q
Va at 2600#
A
101 KIAS
13
Q
Vfe
A
10 degrees- 140 KIAS
20 degrees-120 KIAS
30 degrees-100 KIAS
14
Q
Max TOW
A
3100#
15
Q
Max Landing weight
A
2950#